The availability of non-invasive, fast and sensitive technologies for detection of circulating cancer cells is still a critical need of clinical oncology, particularly for diagnosis of aggressive and highly metastatic tumors, like malignant melanoma. Here we present the first nested polymerase chain reaction process carried out by a microfabricated, hybrid plastic-glass microfluidic chip on the tyrosinase gene, a predictive marker for melanoma diagnosis. The device is a hybrid system consisting of a glass microchannel embedded in an elastomeric matrix, and operating in flow-oscillating modality on a droplet of biological sample. The convection heat transfer and the temperature distribution inside the carrier fluid in the device are investigated. The oil responds to temperature changes with a characteristic time around 53 s, and exhibits three different thermal gradients along the capillary, with temperature variations below 4 degrees C in correspondence of heater electrodes. The sample heating/cooling rates in the chip are as high as 16 degrees C/s, allowing rapid processes. The nested polymerase chain reaction process is performed in less than 50 min, namely more than four times faster than in a standard thermocycler. The rapidity of the analysis method, combined with the simple and low-cost fabrication, reduced sample evaporation, and flexibility of the overall microfluidic platform, make it promising for the detection of events of tumor spreading.

Rapid nested-PCR for tyrosinase gene detection on chip

A Polini;D Pisignano
2011

Abstract

The availability of non-invasive, fast and sensitive technologies for detection of circulating cancer cells is still a critical need of clinical oncology, particularly for diagnosis of aggressive and highly metastatic tumors, like malignant melanoma. Here we present the first nested polymerase chain reaction process carried out by a microfabricated, hybrid plastic-glass microfluidic chip on the tyrosinase gene, a predictive marker for melanoma diagnosis. The device is a hybrid system consisting of a glass microchannel embedded in an elastomeric matrix, and operating in flow-oscillating modality on a droplet of biological sample. The convection heat transfer and the temperature distribution inside the carrier fluid in the device are investigated. The oil responds to temperature changes with a characteristic time around 53 s, and exhibits three different thermal gradients along the capillary, with temperature variations below 4 degrees C in correspondence of heater electrodes. The sample heating/cooling rates in the chip are as high as 16 degrees C/s, allowing rapid processes. The nested polymerase chain reaction process is performed in less than 50 min, namely more than four times faster than in a standard thermocycler. The rapidity of the analysis method, combined with the simple and low-cost fabrication, reduced sample evaporation, and flexibility of the overall microfluidic platform, make it promising for the detection of events of tumor spreading.
2011
Istituto Nanoscienze - NANO
Istituto Nanoscienze - NANO
Tyrosinase
Microfluidics
Nested-PCR
Melanoma
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/74198
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact