One of the instruments on the International X-ray Observatory (IXO), under study with NASA, ESA and JAXA, is the X-ray Microcalorimeter Spectrometer (XMS). This instrument, which will provide high spectral resolution images, is based on X-ray micro-calorimeters with Transition Edge Sensor (TES) with absorbers that consist of metal and semi-metal layers and a multiplexed SQUID readout. The requirements for this instrument are demanding. In the central array (40 x 40 pixels) an energy resolution of <2.5 eV is required, whereas the energy resolution of the outer array is more relaxed (approximate to 10 eV) but the detection elements have to be a factor 16 larger in order to keep the number of read-out channels acceptable for a cryogenic instrument. Due to the large collection area of the IXO optics, the XMS instrument must be capable of processing high counting rates, while maintaining the spectral resolution and a low deadtime. In addition, an anti-coincidence detector is required to suppress the particle-induced background. In this paper we will summarize the instrument status and performance. We will describe the results of design studies for the focal plane assembly and the cooling systems. Also the system and its required spacecraft resources will be given.

The x-ray microcalorimeter spectrometer onboard of IXO

G Torrioli
2010

Abstract

One of the instruments on the International X-ray Observatory (IXO), under study with NASA, ESA and JAXA, is the X-ray Microcalorimeter Spectrometer (XMS). This instrument, which will provide high spectral resolution images, is based on X-ray micro-calorimeters with Transition Edge Sensor (TES) with absorbers that consist of metal and semi-metal layers and a multiplexed SQUID readout. The requirements for this instrument are demanding. In the central array (40 x 40 pixels) an energy resolution of <2.5 eV is required, whereas the energy resolution of the outer array is more relaxed (approximate to 10 eV) but the detection elements have to be a factor 16 larger in order to keep the number of read-out channels acceptable for a cryogenic instrument. Due to the large collection area of the IXO optics, the XMS instrument must be capable of processing high counting rates, while maintaining the spectral resolution and a low deadtime. In addition, an anti-coincidence detector is required to suppress the particle-induced background. In this paper we will summarize the instrument status and performance. We will describe the results of design studies for the focal plane assembly and the cooling systems. Also the system and its required spacecraft resources will be given.
2010
Istituto di fotonica e nanotecnologie - IFN
SPIE - Space Telescopes and Instrumentation 2010: Ultraviolet to Gamma Ray
San Diego (USA)
43
none
W den Herder, J; Bruin, M; Gottardi, L; den Hartog, R; Hoevers, H; de Korte, P; van der Kuur, J; H Nieland, J; L Kelley, H van WeersR; R Bandler, S; R...espandi
273
info:eu-repo/semantics/conferenceObject
04 Contributo in convegno::04.01 Contributo in Atti di convegno
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/80076
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 6
social impact