A grazing-incidence spectrometer-monochromator for diagnostics and application of the extreme-ultraviolet (EUV) and soft-x-ray high-order harmonics generated by the interaction between a few-optical-cycle laser pulse and a gas jet has been fabricated. We address the necessity of high-resolution spectral and spatial analyses of the high-order harmonics as well as their use as short EUV backlighters in pump-probe experiments. The spectrometer that we present uses a variable-line-spaced flat grating illuminated in the converging light coming from a toroidal mirror. The spectrum is stigmatic, and the focal surface is almost flat in a wide spectral region. The detector is a microchannel plate intensifier with a phosphor screen optically coupled to a CCD camera; it can be moved by means of a linear drive to acquire different portions of the spectrum in the 5-75-nm region. The resolution is almost limited by the pixel size of the detector. We apply the same optical scheme to achieve a constant-deviation-angle monochromator by substituting an exit slit for the detector block: The rotation of the grating gives the spectral scanning. A monochromator for the 5-50 nm spectral region is achieved.

Optical design of a spectrometer-monochromator for the extreme-ultraviolet and soft-x-ray emission of high-order harmonics

L Poletto;P Villoresi
2003

Abstract

A grazing-incidence spectrometer-monochromator for diagnostics and application of the extreme-ultraviolet (EUV) and soft-x-ray high-order harmonics generated by the interaction between a few-optical-cycle laser pulse and a gas jet has been fabricated. We address the necessity of high-resolution spectral and spatial analyses of the high-order harmonics as well as their use as short EUV backlighters in pump-probe experiments. The spectrometer that we present uses a variable-line-spaced flat grating illuminated in the converging light coming from a toroidal mirror. The spectrum is stigmatic, and the focal surface is almost flat in a wide spectral region. The detector is a microchannel plate intensifier with a phosphor screen optically coupled to a CCD camera; it can be moved by means of a linear drive to acquire different portions of the spectrum in the 5-75-nm region. The resolution is almost limited by the pixel size of the detector. We apply the same optical scheme to achieve a constant-deviation-angle monochromator by substituting an exit slit for the detector block: The rotation of the grating gives the spectral scanning. A monochromator for the 5-50 nm spectral region is achieved.
2003
Istituto di fotonica e nanotecnologie - IFN
INFM
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/8118
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 26
social impact