The design and installation of the upgraded diagnostic system for ECE perpendicular and oblique measurements at JET is presented in this paper. The system includes three lines of sight with different toroidal angles and a six channel Martin-Puplett fast scanning interferometer.

The Multichannel Extension Of The Martin-Puplett Interferometer For Perpendicular And Oblique ECE Measurements On JET

C Sozzi;A Simonetto;S Garavaglia;
2006

Abstract

The design and installation of the upgraded diagnostic system for ECE perpendicular and oblique measurements at JET is presented in this paper. The system includes three lines of sight with different toroidal angles and a six channel Martin-Puplett fast scanning interferometer.