Because of their low implementation costs, optimum responsiveness and widespread availability, controller area networks (CANs) are being more and more used today for supporting communications in real-time systems. However, under heavy traffic conditions, the access protocol of a CAN may exhibit a quite unfair behaviour, in particular when the control applications require that the same quality of service be ensured to a number of different objects. In this paper, a new technique is proposed, called MUST (medium utilisation state tracking), which is based on CANs and introduces few changes to the original protocol. Such a solution is able to ensure a very fair behaviour $which resembles the one obtained in token-based networks - while maintaining, at the same time, the reduced access delays typical of CANs when operating in low traffic conditions.

MUST: a Quasi-Round Robin Access Scheme for CAN Networks

G Cena;A Valenzano
2000

Abstract

Because of their low implementation costs, optimum responsiveness and widespread availability, controller area networks (CANs) are being more and more used today for supporting communications in real-time systems. However, under heavy traffic conditions, the access protocol of a CAN may exhibit a quite unfair behaviour, in particular when the control applications require that the same quality of service be ensured to a number of different objects. In this paper, a new technique is proposed, called MUST (medium utilisation state tracking), which is based on CANs and introduces few changes to the original protocol. Such a solution is able to ensure a very fair behaviour $which resembles the one obtained in token-based networks - while maintaining, at the same time, the reduced access delays typical of CANs when operating in low traffic conditions.
2000
Istituto di Elettronica e di Ingegneria dell'Informazione e delle Telecomunicazioni - IEIIT
Inglese
3rd IEEE International Workshop on Factory Communication Systems (WFCS 2000)
59
66
8
0-7803-6500-3
http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=882534
IEEE-Institute Of Electrical And Electronics Engineers Inc.
Piscataway
STATI UNITI D'AMERICA
Sì, ma tipo non specificato
6-8 Settembre 2000
Porto
Access protocols
Controller Area Network (CAN)
factory communication systems
2
none
Cena, G; Valenzano, A
273
info:eu-repo/semantics/conferenceObject
04 Contributo in convegno::04.01 Contributo in Atti di convegno
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/879
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact