Magnetic resonance imaging is a diagnostic technique widely used in medicine and showing a growing impact in cardiology. Biological effects associated to magnetic resonance electromagnetic fields have received far little attention, but it cannot be ruled out that these fields can alter DNA structure. The present study aimed at to identify possible DNA damage induced by magnetic resonance scan in humans. Lymphocyte cultures from healthy subjects had been exposed into magnetic resonance device for different times and under different variable magnetic exposure in order to build dose-effect curves, using micronuclei induction as biological marker. Replicate cultureswere also left for 24 h at room temperature before stimulation, to verify possible damage recovery. Furthermore, micronuclei induction and recovery up to 120 h have been also evaluated in circulating lymphocytes of individuals after cardiac scan. A dose-dependent increase of micronuclei frequency was observed in vitro. However after 24 h, the frequency returns to control value when the exposure is within diagnostic dosage. After in vivo scan, a significant increase in micronuclei is found till 24 h, after the frequencies slowly return to control value.

Is the genotoxic effect of magnetic resonance negligible? Low persistence of micronucleus frequency in lymphocytes of individuals after cardiac scan

Valentina Hartwig;Giulio Giovannetti;
2008

Abstract

Magnetic resonance imaging is a diagnostic technique widely used in medicine and showing a growing impact in cardiology. Biological effects associated to magnetic resonance electromagnetic fields have received far little attention, but it cannot be ruled out that these fields can alter DNA structure. The present study aimed at to identify possible DNA damage induced by magnetic resonance scan in humans. Lymphocyte cultures from healthy subjects had been exposed into magnetic resonance device for different times and under different variable magnetic exposure in order to build dose-effect curves, using micronuclei induction as biological marker. Replicate cultureswere also left for 24 h at room temperature before stimulation, to verify possible damage recovery. Furthermore, micronuclei induction and recovery up to 120 h have been also evaluated in circulating lymphocytes of individuals after cardiac scan. A dose-dependent increase of micronuclei frequency was observed in vitro. However after 24 h, the frequency returns to control value when the exposure is within diagnostic dosage. After in vivo scan, a significant increase in micronuclei is found till 24 h, after the frequencies slowly return to control value.
2008
Istituto di Fisiologia Clinica - IFC
Genotoxic effect
Magnetic resonance
Micronuclei
File in questo prodotto:
File Dimensione Formato  
prod_181848-doc_22782.pdf

non disponibili

Descrizione: Articolo pubblicato
Dimensione 170.33 kB
Formato Adobe PDF
170.33 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/885
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 60
social impact