Myocardial perfusion images can be affected by the dark rim artifact. This study aimed to evaluate the effects of the spatial resolution and heart rate on the transmural extent of the artifact. Six pigs under anesthesia were scanned at 1.5T using an echo-planar imaging/fast gradient echo sequence with a nonselective saturation preparation pulse. Three short-axis slices were acquired every heart beat during the first pass of a contrast agent bolus. Two different in-plane spatial resolutions (2.65 and 3.75 mm) and two different heart rates (normal and tachycardia) were used, generating a set of four perfusion scans. The percentage drop of signal in the subendocardium compared to the epicardium and the transmural extent of the artifact were extracted. Additionally, the signal-to-noise and the contrast-to-noise ratios were evaluated. The signal drop as well as the width of the dark rim artifact increased with decreased spatial resolution and with increased heart rates. No significant slice-to-slice variability was detected for signal drop and width of the rim within the four considered groups. signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) ratios decreased with increasing spatial resolution. In conclusion, low spatial and temporal resolution could be correlated with increased extent of the dark-rim artifact and with lower SNR and CNR.

Myocardial First-Pass Perfusion: Influence of Spatial Resolution and Heart Rate on the Dark Rim Artifact

Positano Vincenzo;Burchielli Silvia;
2011

Abstract

Myocardial perfusion images can be affected by the dark rim artifact. This study aimed to evaluate the effects of the spatial resolution and heart rate on the transmural extent of the artifact. Six pigs under anesthesia were scanned at 1.5T using an echo-planar imaging/fast gradient echo sequence with a nonselective saturation preparation pulse. Three short-axis slices were acquired every heart beat during the first pass of a contrast agent bolus. Two different in-plane spatial resolutions (2.65 and 3.75 mm) and two different heart rates (normal and tachycardia) were used, generating a set of four perfusion scans. The percentage drop of signal in the subendocardium compared to the epicardium and the transmural extent of the artifact were extracted. Additionally, the signal-to-noise and the contrast-to-noise ratios were evaluated. The signal drop as well as the width of the dark rim artifact increased with decreased spatial resolution and with increased heart rates. No significant slice-to-slice variability was detected for signal drop and width of the rim within the four considered groups. signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) ratios decreased with increasing spatial resolution. In conclusion, low spatial and temporal resolution could be correlated with increased extent of the dark-rim artifact and with lower SNR and CNR.
2011
Istituto di Fisiologia Clinica - IFC
Myocardial Perfusion
Cardiovascular magnetic resonance
Dark Rim Artifact
File in questo prodotto:
File Dimensione Formato  
prod_202647-doc_44983.pdf

solo utenti autorizzati

Descrizione: Myocardial First-Pass Perfusion: Influence of Spatial Resolution and Heart Rate on the Dark Rim Artifact
Dimensione 1.35 MB
Formato Adobe PDF
1.35 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/9949
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? ND
social impact