We have realised and tested a 40 litres (29 cm diameter, 61 cm height) emission test chamber made with a standard chemical reactor vessel. This approach achieves an economical and very flexible design, intended for operation in a temperature-controlled area, that is useful for volatile organic compounds (VOCs) emissions and sinks measurements. The chamber internal atmosphere is in contact only with borosilicate glass, stainless steel and PTFE sealing ring. It is designed for dynamic (constant air flow exchange) operation, but it is useful as well for static experiments. The internal mixing fan is driven by a standard external laboratory stirrer with digital speed control, allowing a minimum impact of drive operation on the chamber atmosphere. Preliminary test for air mixing, losses and sinks are described with an example of flooring PVC emission test data modelled with a double exponential regression.

A volatile organic compounds emission test chamber based on a standard chemical reactor vessel

A Strini;L Bignami
1999

Abstract

We have realised and tested a 40 litres (29 cm diameter, 61 cm height) emission test chamber made with a standard chemical reactor vessel. This approach achieves an economical and very flexible design, intended for operation in a temperature-controlled area, that is useful for volatile organic compounds (VOCs) emissions and sinks measurements. The chamber internal atmosphere is in contact only with borosilicate glass, stainless steel and PTFE sealing ring. It is designed for dynamic (constant air flow exchange) operation, but it is useful as well for static experiments. The internal mixing fan is driven by a standard external laboratory stirrer with digital speed control, allowing a minimum impact of drive operation on the chamber atmosphere. Preliminary test for air mixing, losses and sinks are described with an example of flooring PVC emission test data modelled with a double exponential regression.
1999
Istituto per le Tecnologie della Costruzione - ITC
Inglese
Indoor Air 99
The 8th International Conference on Indoor Air Quality and Climate
137
142
1-86081-295-3
Construction Research Communications Ltd.
London
REGNO UNITO DI GRAN BRETAGNA
Sì, ma tipo non specificato
8-13 August 1999
Edimburgh, Scotland
2
none
A. Strini; E. Mapelli; L. Bignami
273
info:eu-repo/semantics/conferenceObject
04 Contributo in convegno::04.01 Contributo in Atti di convegno
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/116228
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact