This paper reports the results of a study performed to develop a rapid and straightforward chromatographic method for the identification and dosage of 5-hydroxymethyl-2-fbraldehyde (HMF) and 2-furaldehyde (FA), which are recognized indices of deteriorative changes in commercially processed food. The method employs a Supelco microbore reversed phase column (300 x 1.0 mm I.D.), eluted isocratically with a 94:6 (vh) water/acetonitrile mixture at flow rate of 60 pL/min. Sample is detected at 280 nm in a micro flow cell of 300 nl. Peak purity and identification is assessed by comparing the UV spectra monitored at two points through the chromatographic peak in continuous flow mode in the range fiom 200 to 400 nm. This method is successfully applied to the identification and quantitative determination of HMF and FA in alcoholic and nonalcoholic beverages by an internal standard method without any sample pretreatment

Identification and dosage of 2-Furaldehyde and 5-Hydroxymethyl-2-Furaldehyde in beverage by reversed phase chromatography with a microbore column

Isabella Nicoletti;Danilo Corradini
1996

Abstract

This paper reports the results of a study performed to develop a rapid and straightforward chromatographic method for the identification and dosage of 5-hydroxymethyl-2-fbraldehyde (HMF) and 2-furaldehyde (FA), which are recognized indices of deteriorative changes in commercially processed food. The method employs a Supelco microbore reversed phase column (300 x 1.0 mm I.D.), eluted isocratically with a 94:6 (vh) water/acetonitrile mixture at flow rate of 60 pL/min. Sample is detected at 280 nm in a micro flow cell of 300 nl. Peak purity and identification is assessed by comparing the UV spectra monitored at two points through the chromatographic peak in continuous flow mode in the range fiom 200 to 400 nm. This method is successfully applied to the identification and quantitative determination of HMF and FA in alcoholic and nonalcoholic beverages by an internal standard method without any sample pretreatment
1996
Istituto per i Sistemi Biologici - ISB (ex IMC)
Alcoholic and non-alcoholic beverages
HMF
HPLC
microbore column
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/12449
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact