A full-scale (30 cubic meters) test chamber was developed for the study of the effects of volatile organic compounds (VOC) emissions from materials in real indoor environments. This test chamber is located outdoor and was designed to optimize the realism of the test. The chamber is supplied with unfiltered air and is realized in concrete with gypsum-finished walls and ceiling. The air supply system allows the operation in static conditions (no air change) and dynamic conditions (controlled air change). An arbitrary time schedule of different air change rates can be established in order to simulate variable indoor conditions. A ceiling fan assures the proper air mixing. The temperature control system is based on electrical heating elements in winter, while in summer the temperature is given by a balance of the solar radiation, the thermal inertia of the chamber structure, the temperature of external air and the air change rate.

Full scale test system for indoor impact study of volatile organic compound emissions from buildin materials

A Strini
2002

Abstract

A full-scale (30 cubic meters) test chamber was developed for the study of the effects of volatile organic compounds (VOC) emissions from materials in real indoor environments. This test chamber is located outdoor and was designed to optimize the realism of the test. The chamber is supplied with unfiltered air and is realized in concrete with gypsum-finished walls and ceiling. The air supply system allows the operation in static conditions (no air change) and dynamic conditions (controlled air change). An arbitrary time schedule of different air change rates can be established in order to simulate variable indoor conditions. A ceiling fan assures the proper air mixing. The temperature control system is based on electrical heating elements in winter, while in summer the temperature is given by a balance of the solar radiation, the thermal inertia of the chamber structure, the temperature of external air and the air change rate.
2002
Istituto per le Tecnologie della Costruzione - ITC
Inglese
Hal Levin
Proceedings Indoor Air 2002
Indoor Air 2002 - 9th International Conference on Indoor Air Quality and Climate
578
583
0-9721832-0-5
Indoor Air 2002
Santa Cruz, CA
STATI UNITI D'AMERICA
Sì, ma tipo non specificato
June 30-July 5, 2002
Monterey, CA, USA
full-scale chamber
sink
superficial air speed
testing house
VOC material emissions
4
none
Antonelli, L; Mapelli, E; Sanguinetti, S; Strini, A
273
info:eu-repo/semantics/conferenceObject
04 Contributo in convegno::04.01 Contributo in Atti di convegno
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/125333
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact