In this work we compare the B electrical activity in crystalline (c-Ge) and preamorphized Ge (PAI-Ge), in order to elucidate the activation mechanisms involved in the two cases and evidence the possible advantages of an approach over to the other. With this aim, we independently measured the hole fluence and the sheet resistance. thus extracting the carrier mobility, as a function of the implanted B fluence. In particular, we evidenced that it is possible to reproduce the metastability of the PAI process implanting B in c-Ge at very high fluences. However, by properly choosing the implantation conditions in c-Ge, in such a way to disable dynamic annealing during implantation, the activation of B can be raised up to the level attainable in PAI-Ge also for lower B fluences. Finally, the thermal evolution of the formed junction was tested, evidencing a high stability under annealing up to 550 degrees C in both c- and PAI-Ge. (C) 2008 Elsevier B.V. All rights reserved.

B electrical activation in crystalline and preamorphized Ge

Bruno E;Impellizzeri G;Mirabella S;Irrera A;
2008

Abstract

In this work we compare the B electrical activity in crystalline (c-Ge) and preamorphized Ge (PAI-Ge), in order to elucidate the activation mechanisms involved in the two cases and evidence the possible advantages of an approach over to the other. With this aim, we independently measured the hole fluence and the sheet resistance. thus extracting the carrier mobility, as a function of the implanted B fluence. In particular, we evidenced that it is possible to reproduce the metastability of the PAI process implanting B in c-Ge at very high fluences. However, by properly choosing the implantation conditions in c-Ge, in such a way to disable dynamic annealing during implantation, the activation of B can be raised up to the level attainable in PAI-Ge also for lower B fluences. Finally, the thermal evolution of the formed junction was tested, evidencing a high stability under annealing up to 550 degrees C in both c- and PAI-Ge. (C) 2008 Elsevier B.V. All rights reserved.
2008
INFM
Inglese
154
56
59
4
Sì, ma tipo non specificato
ION-IMPLANTATION
GERMANIUM
DIFFUSION
BORON
DAMAGE
6
info:eu-repo/semantics/article
262
Bruno, E; Impellizzeri, G; Mirabella, S; Piro, Am; Irrera, A; Grimaldi, Mg
01 Contributo su Rivista::01.01 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/159119
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 4
social impact