The ITER Neutral Beam Test Facility (PRIMAPadova Research on ITER Megavolt Accelerator) is planned to be built at Consorzio RFX (Padova, Italy). PRIMA includes two experimental devices: a full-size plasma source with low voltage extraction called SPIDER (Source for Production of Ions of Deuterium Extracted from RF plasma) and a full-size neutral beam injector at full beam power called MÍTICA (Megavolt ITER Injector Concept Advancement). The beam source components are exposed to high and focused heat loads during beam production, and they are actively cooled, being at high voltage, by ultrapure water, which flows through cooling channels machined inside the components. The high power loads, the complexity of the cooling circuits, and their small, rectangular cross sections are design critical issues. The results of the tests carried out on the single cooling channel prototypes (SCPs) for the SPIDER accelerator grids and their performances in terms of pressure drop and heat exchange calculation are presented. The SCPs have been tested in environmental conditions similar to injector ones, i.e., they have been subjected to thermal loads up to the average heat power density of 1 MW/m 2, in a vacuum environment (0.5 Pa). The experimental results have been cross-checked with computational fluid dynamics analyses and analytical models.

Thermo fluid dynamics tests on the single channel prototypes for the spider grids

Piero Agostinetti;Moreno Maniero;Modesto Moressa;
2012

Abstract

The ITER Neutral Beam Test Facility (PRIMAPadova Research on ITER Megavolt Accelerator) is planned to be built at Consorzio RFX (Padova, Italy). PRIMA includes two experimental devices: a full-size plasma source with low voltage extraction called SPIDER (Source for Production of Ions of Deuterium Extracted from RF plasma) and a full-size neutral beam injector at full beam power called MÍTICA (Megavolt ITER Injector Concept Advancement). The beam source components are exposed to high and focused heat loads during beam production, and they are actively cooled, being at high voltage, by ultrapure water, which flows through cooling channels machined inside the components. The high power loads, the complexity of the cooling circuits, and their small, rectangular cross sections are design critical issues. The results of the tests carried out on the single cooling channel prototypes (SCPs) for the SPIDER accelerator grids and their performances in terms of pressure drop and heat exchange calculation are presented. The SCPs have been tested in environmental conditions similar to injector ones, i.e., they have been subjected to thermal loads up to the average heat power density of 1 MW/m 2, in a vacuum environment (0.5 Pa). The experimental results have been cross-checked with computational fluid dynamics analyses and analytical models.
2012
Istituto gas ionizzati - IGI - Sede Padova
Inglese
62
1
164
170
7
http://epubs.ans.org/?a=14130
Sì, ma tipo non specificato
Fluid dynamics test
Prototypes
SPIDER
This work was set up in collaboration and under financial support of Fusion for Energy. / Proceedings of the Fifteenth International Conference on Fusion Reactor Materials, Part A: Fusion Technology.
7
info:eu-repo/semantics/article
262
Rizzolo, Andrea; Agostinetti, Piero; Breda, Mauro; Maniero, Moreno; Marcuzzi, Diego; Moressa, Modesto; Valente, Matteo
01 Contributo su Rivista::01.01 Articolo in rivista
none
   EU Fusion for ITER Applications
   EUFORIA
   FP7
   211804
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/231552
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 4
social impact