The new muon (g-2) experiment E989 at Fermilab will be equipped with a laser calibration system for all the 1296 channels of the calorimeters. An integrating sphere and an alternative system based on an engineered diffuser have been considered as possible light distributors for the experiment. We present here a detailed comparison of the two based on temporal response, spatial uniformity, transmittance and time stability. (C) 2015 Elsevier B.V. All rights reserved.

Test of candidate light distributors for the muon (g-2) laser calibration system

F Baffigi;C Ferrari;A Fioretti;L Fulgentini;C Gabbanini;L A Gizzi;P Koester;L Labate;
2015

Abstract

The new muon (g-2) experiment E989 at Fermilab will be equipped with a laser calibration system for all the 1296 channels of the calorimeters. An integrating sphere and an alternative system based on an engineered diffuser have been considered as possible light distributors for the experiment. We present here a detailed comparison of the two based on temporal response, spatial uniformity, transmittance and time stability. (C) 2015 Elsevier B.V. All rights reserved.
2015
Istituto Nazionale di Ottica - INO
Electromagnetic calorimeter
Integrating sphere
Diffuser
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/297391
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 13