The absorbance spectra of 12 corneal tissues were measured in the 330 to 700 nm wavelength range using a purpose-designed spectrophotometry setup before and after transepithelial corneal soaking with a 15% dextran-enriched riboflavin 0.1% solution (n = 6) or a hypotonic dextran-free riboflavin 0.1% solution (n = 6). Both ophthalmic solutions contained ethylenediaminetetraacetic acid and trometamol as enhancers. In addition, 4 deepithelialized corneal tissues underwent stromal soaking with a 20% dextran-enriched riboflavin 0.1% solution and were used as controls. All the riboflavin solutions were applied topically for 30 minutes. The stromal concentration of riboflavin was quantified by analysis of absorbance spectra of the cornea collected before and after application of each solution. The mean stromal riboflavin concentration was 0.012% ± 0.003% (SD), 0.0005% ± 0.0003% (P < .001), and 0.004% ± 0.001% (P < .01) in tissues soaked with 20% dextran-enriched, 15% dextran-enriched, and hypotonic dextran-free solutions, respectively. The difference of stromal riboflavin concentration between the 2 transepithelial solutions was statistically significant (P < .01). Dextran-enriched solutions required complete corneal deepithelialization to permit effective stromal soaking with riboflavin. Nevertheless, riboflavin in hypotonic dextran-free solution with enhancers permeates across stroma through an intact epithelium

Ultraviolet A - visible spectral absorbance of the human cornea after transepithelial soaking with dextran-enriched and dextran-freeriboflavin 0.1% ophthalmic solutions

N Micali;V VILLARI;G Pucci;R Barberi;G Lombardo
2015

Abstract

The absorbance spectra of 12 corneal tissues were measured in the 330 to 700 nm wavelength range using a purpose-designed spectrophotometry setup before and after transepithelial corneal soaking with a 15% dextran-enriched riboflavin 0.1% solution (n = 6) or a hypotonic dextran-free riboflavin 0.1% solution (n = 6). Both ophthalmic solutions contained ethylenediaminetetraacetic acid and trometamol as enhancers. In addition, 4 deepithelialized corneal tissues underwent stromal soaking with a 20% dextran-enriched riboflavin 0.1% solution and were used as controls. All the riboflavin solutions were applied topically for 30 minutes. The stromal concentration of riboflavin was quantified by analysis of absorbance spectra of the cornea collected before and after application of each solution. The mean stromal riboflavin concentration was 0.012% ± 0.003% (SD), 0.0005% ± 0.0003% (P < .001), and 0.004% ± 0.001% (P < .01) in tissues soaked with 20% dextran-enriched, 15% dextran-enriched, and hypotonic dextran-free solutions, respectively. The difference of stromal riboflavin concentration between the 2 transepithelial solutions was statistically significant (P < .01). Dextran-enriched solutions required complete corneal deepithelialization to permit effective stromal soaking with riboflavin. Nevertheless, riboflavin in hypotonic dextran-free solution with enhancers permeates across stroma through an intact epithelium
2015
Istituto per i Processi Chimico-Fisici - IPCF
Absorbance
Riboflavin
human cornea
File in questo prodotto:
File Dimensione Formato  
prod_344108-doc_160592.pdf

solo utenti autorizzati

Descrizione: Ultraviolet A - visible spectral absorbance of the human cornea
Tipologia: Versione Editoriale (PDF)
Dimensione 669.5 kB
Formato Adobe PDF
669.5 kB Adobe PDF   Visualizza/Apri   Richiedi una copia