A plastic optical fibre biosensor based on surface plasmonresonance for the detection of C-reactive protein (CRP)in serum is proposed. The biosensor was integrated into ahome-made thermo-stabilized microfluidic system that al-lows avoiding any thermal and/or mechanical fluctuationand maintaining the best stable conditions during themeasurements. A working range of 0.006-70 mg L-1and alimit of detection of 0.009 mg L-1were achieved. Theseresults are among the best compared to other SPR-basedbiosensors for CRP detection, especially considering thatthey were achieved in a real and complex medium, i.e.serum. In addition, since the sensor performances satisfythose requested in physiologically-relevant clinical appli-cations, the whole biosensing platform could well addresshigh sensitive, easy to realize, real-time, label-free, porta-ble and low cost diagnosis of CRP for future lab-on-a-chipapplications.

SPR-based plastic optical fibre biosensor for the detection of C-reactive protein in serum

Chiavaioli F.;Trono C.
;
Tombelli S.;Giannetti A.;Baldini F.
2016

Abstract

A plastic optical fibre biosensor based on surface plasmonresonance for the detection of C-reactive protein (CRP)in serum is proposed. The biosensor was integrated into ahome-made thermo-stabilized microfluidic system that al-lows avoiding any thermal and/or mechanical fluctuationand maintaining the best stable conditions during themeasurements. A working range of 0.006-70 mg L-1and alimit of detection of 0.009 mg L-1were achieved. Theseresults are among the best compared to other SPR-basedbiosensors for CRP detection, especially considering thatthey were achieved in a real and complex medium, i.e.serum. In addition, since the sensor performances satisfythose requested in physiologically-relevant clinical appli-cations, the whole biosensing platform could well addresshigh sensitive, easy to realize, real-time, label-free, porta-ble and low cost diagnosis of CRP for future lab-on-a-chipapplications.
2016
Istituto di Fisica Applicata - IFAC
C-reactive protein
Microfluidic system
Plastic optical fibre
Serum
Surface plasmon resonance
File in questo prodotto:
File Dimensione Formato  
prod_355629-doc_115537.pdf

solo utenti autorizzati

Descrizione: SPR-based plastic optical fibre biosensor for the detection of C-reactive protein in serum
Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 233.18 kB
Formato Adobe PDF
233.18 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
prod_355629-doc_188838.pdf

accesso aperto

Descrizione: SPR-based plastic optical fibre biosensor for the detection of C-reactive protein in serum
Tipologia: Documento in Pre-print
Licenza: Altro tipo di licenza
Dimensione 660.99 kB
Formato Adobe PDF
660.99 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/317873
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 95
  • ???jsp.display-item.citation.isi??? 28
social impact