A fluorescence polarization (FP) immunoassay has been optimized and validated for rapid quantification of T-2 and HT-2 toxins in both unprocessed cereals, including oats, barley and rye, and cereal-based products for direct human consumption, such as oat flakes, oats crispbread and pasta. Samples were extracted with 90 % methanol, and the extract was filtered and diluted with water or sodium chloride solution prior to the FP immunoassay. Overall mean recoveries from spiked oats, rye, barley, oat flakes, oats crispbread and pasta ranged from 101 to 107 %, with relative standard deviations lower than 7 %. Limits of detection (LODs) of the FP immunoassay were 70 mu g/kg for oats, 40 mu g/kg for oat flakes and barley, 25 mu g/kg for pasta and 20 mu g/kg for rye and oats crispbread. The trueness of the immunoassay was assessed by using two oat and oat flake reference materials for T-2 and HT-2 toxins, showing good accuracy and precision. Good correlations (r > 0.953) were observed between T-2 and HT-2 toxin contents in naturally and artificially contaminated samples determined by both FP immunoassay and ultra-high-performance liquid chromatography (UHPLC) with immunoaffinity column cleanup used as reference method. These results, combined with rapidity and simplicity of the assay, show that the optimized assay is suitable for high-throughput screening, as well as for reliable quantitative determination of T-2 and HT-2 toxins in cereals and cereal-based products.
Optimization and Validation of a Fluorescence Polarization Immunoassay for Rapid Detection of T-2 and HT-2 Toxins in Cereals and Cereal-Based Products
Porricelli Anna Chiara R;Lippolis Vincenzo;Valenzano Stefania;Cortese Marina;Pascale Michelangelo
2016
Abstract
A fluorescence polarization (FP) immunoassay has been optimized and validated for rapid quantification of T-2 and HT-2 toxins in both unprocessed cereals, including oats, barley and rye, and cereal-based products for direct human consumption, such as oat flakes, oats crispbread and pasta. Samples were extracted with 90 % methanol, and the extract was filtered and diluted with water or sodium chloride solution prior to the FP immunoassay. Overall mean recoveries from spiked oats, rye, barley, oat flakes, oats crispbread and pasta ranged from 101 to 107 %, with relative standard deviations lower than 7 %. Limits of detection (LODs) of the FP immunoassay were 70 mu g/kg for oats, 40 mu g/kg for oat flakes and barley, 25 mu g/kg for pasta and 20 mu g/kg for rye and oats crispbread. The trueness of the immunoassay was assessed by using two oat and oat flake reference materials for T-2 and HT-2 toxins, showing good accuracy and precision. Good correlations (r > 0.953) were observed between T-2 and HT-2 toxin contents in naturally and artificially contaminated samples determined by both FP immunoassay and ultra-high-performance liquid chromatography (UHPLC) with immunoaffinity column cleanup used as reference method. These results, combined with rapidity and simplicity of the assay, show that the optimized assay is suitable for high-throughput screening, as well as for reliable quantitative determination of T-2 and HT-2 toxins in cereals and cereal-based products.File | Dimensione | Formato | |
---|---|---|---|
prod_362022-doc_119185.pdf
solo utenti autorizzati
Descrizione: Optimization and Validation of a Fluorescence Polarization Immunoassay for Rapid Detection of T-2 and HT-2 Toxins in Cereals and Cereal-Based Products
Tipologia:
Versione Editoriale (PDF)
Dimensione
564.64 kB
Formato
Adobe PDF
|
564.64 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.