This paper reports on a seismic monitoring experiment conducted on the bell tower of the San Frediano Church in Lucca, Italy. The tower, dating back to the 11th century, has been fitted along its height with four triaxial seismometric stations which were then left active on the tower for four days. The data from the monitoring system have been processed via the Stochastic Subspace Identification Method, implemented in the MACEC code, which has allowed extracting the tower's natural frequencies, mode shapes and damping ratios and their variations over time. A finite element model of the structure has been created via the NOSA-ITACA code and updated to fit the experimental data. The analysis has proved the effectiveness of the tools employed to assess the dynamic behaviour of ancient masonry towers.

Assessment of the dynamic behaviour of an ancient masonry tower in Lucca via ambient vibrations

Azzara R. M.;Girardi M.;Padovani C.;Pellegrini D.
2016

Abstract

This paper reports on a seismic monitoring experiment conducted on the bell tower of the San Frediano Church in Lucca, Italy. The tower, dating back to the 11th century, has been fitted along its height with four triaxial seismometric stations which were then left active on the tower for four days. The data from the monitoring system have been processed via the Stochastic Subspace Identification Method, implemented in the MACEC code, which has allowed extracting the tower's natural frequencies, mode shapes and damping ratios and their variations over time. A finite element model of the structure has been created via the NOSA-ITACA code and updated to fit the experimental data. The analysis has proved the effectiveness of the tools employed to assess the dynamic behaviour of ancient masonry towers.
2016
Istituto di Scienza e Tecnologie dell'Informazione "Alessandro Faedo" - ISTI
Inglese
Structural Analysis of Historical Constructions: Anamnesis, diagnosis, therapy, controls
SAHC 2016 - 10th International Conference on Structural Analysis of Historical Constructions - Anamnesis, diagnosis, therapy, controls
669
675
7
978-1-138-02951-4
https://www.taylorfrancis.com/books/e/9781315616995
Sì, ma tipo non specificato
13-15 September 2016
Leuven, Belgium
Internazionale
Masonry buildings
Structural health monitoring
Numerical methods
Operational modal analysis
J.2 PHYSICAL SCIENCES AND ENGINEERING
6
restricted
Azzara, R. M.; De Roeck, G.; Reynders, E.; Girardi, M.; Padovani, C.; Pellegrini, D.
273
info:eu-repo/semantics/conferenceObject
04 Contributo in convegno::04.01 Contributo in Atti di convegno
File in questo prodotto:
File Dimensione Formato  
prod_358980-doc_117619.pdf

solo utenti autorizzati

Descrizione: Assessment of the dynamic behaviour of an ancient masonry tower in Lucca via ambient vibrations
Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.3 MB
Formato Adobe PDF
1.3 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/325476
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 6
social impact