A rapid fluorescence polarization immunoassay (FPIA) was optimized and validated for the determination of ochratoxin A (OTA) in rye and rye crispbread. Samples were extracted with a mixture of acetonitrile/water (60:40, v/v) and purified by SPE-aminopropyl column clean-up before performing the FPIA. Overall mean recoveries were 86 and 95% for spiked rye and rye crispbread with relative standard deviations lower than 6%. Limits of detection (LOD) of the optimized FPIA was 0.6 mug/kg for rye and rye crispbread, respectively. Good correlations (r > 0.977) were observed between OTA contents in contaminated samples obtained by FPIA and high-performance liquid chromatography (HPLC) with immunoaffinity cleanup used as reference method. Furthermore, single laboratory validation and small-scale collaborative trials were carried out for the determination of OTA in rye according to Regulation 519/2014/EU laying down procedures for the validation of screening methods. The precision profile of the method, cut-off level and rate of false suspect results confirm the satisfactory analytical performances of assay as a screening method. These findings show that the optimized FPIA is suitable for high-throughput screening, and permits reliable quantitative determination of OTA in rye and rye crispbread at levels that fall below the EU regulatory limits.
Determination of Ochratoxin A in Rye and Rye-Based Products by Fluorescence Polarization Immunoassay.
Lippolis Vincenzo;Cortese Marina;Pascale Michelangelo
2017
Abstract
A rapid fluorescence polarization immunoassay (FPIA) was optimized and validated for the determination of ochratoxin A (OTA) in rye and rye crispbread. Samples were extracted with a mixture of acetonitrile/water (60:40, v/v) and purified by SPE-aminopropyl column clean-up before performing the FPIA. Overall mean recoveries were 86 and 95% for spiked rye and rye crispbread with relative standard deviations lower than 6%. Limits of detection (LOD) of the optimized FPIA was 0.6 mug/kg for rye and rye crispbread, respectively. Good correlations (r > 0.977) were observed between OTA contents in contaminated samples obtained by FPIA and high-performance liquid chromatography (HPLC) with immunoaffinity cleanup used as reference method. Furthermore, single laboratory validation and small-scale collaborative trials were carried out for the determination of OTA in rye according to Regulation 519/2014/EU laying down procedures for the validation of screening methods. The precision profile of the method, cut-off level and rate of false suspect results confirm the satisfactory analytical performances of assay as a screening method. These findings show that the optimized FPIA is suitable for high-throughput screening, and permits reliable quantitative determination of OTA in rye and rye crispbread at levels that fall below the EU regulatory limits.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.