This paper presents a laboratory-scale experimental investigation about the laser cleaning of diagnostic first mirrors from tokamak-like contaminants, made of oxidized tungsten compounds with different properties and morphology. The re-deposition of contaminants sputtered from a tokamak first wall onto first mirrors' surfaces could dramatically decrease their reflectivity in an unacceptable way for the proper functioning of plasma diagnostic systems. The laser cleaning technique has been proposed as a solution to tackle this issue. In this work, pulsed laser deposition was exploited to produce rhodium films functional as first mirrors and to deposit onto them contaminants designed to be realistic in reproducing materials expected to be re-deposited on first mirrors in a tokamak environment. The same laser system was also used to perform laser cleaning experiments, exploiting a sample handling procedure that allows one to clean some cm(2) in a few minutes. Cleaning effectiveness was evaluated in terms of specular reflectance recovery and mirror surface integrity. The effect of different laser wavelengths (lambda = 1064, 266 nm) on the cleaning process was also addressed, as well as the impact of multiple contamination/ cleaning cycles on the process outcome. A satisfactory recovery of pristine mirror reflectance (>= 90%) was obtained in the vis-NIR spectral range, avoiding at the same time mirror damaging. The results here presented show the potential of the laser cleaning technique as an attractive solution for the cleaning of diagnostic first mirrors.

Laser cleaning of diagnostic mirrors from tungsten-oxygen tokamak-like contaminants

Uccello A;Dellasega D;Passoni M
2016

Abstract

This paper presents a laboratory-scale experimental investigation about the laser cleaning of diagnostic first mirrors from tokamak-like contaminants, made of oxidized tungsten compounds with different properties and morphology. The re-deposition of contaminants sputtered from a tokamak first wall onto first mirrors' surfaces could dramatically decrease their reflectivity in an unacceptable way for the proper functioning of plasma diagnostic systems. The laser cleaning technique has been proposed as a solution to tackle this issue. In this work, pulsed laser deposition was exploited to produce rhodium films functional as first mirrors and to deposit onto them contaminants designed to be realistic in reproducing materials expected to be re-deposited on first mirrors in a tokamak environment. The same laser system was also used to perform laser cleaning experiments, exploiting a sample handling procedure that allows one to clean some cm(2) in a few minutes. Cleaning effectiveness was evaluated in terms of specular reflectance recovery and mirror surface integrity. The effect of different laser wavelengths (lambda = 1064, 266 nm) on the cleaning process was also addressed, as well as the impact of multiple contamination/ cleaning cycles on the process outcome. A satisfactory recovery of pristine mirror reflectance (>= 90%) was obtained in the vis-NIR spectral range, avoiding at the same time mirror damaging. The results here presented show the potential of the laser cleaning technique as an attractive solution for the cleaning of diagnostic first mirrors.
2016
Istituto di fisica del plasma - IFP - Sede Milano
laser cleaning
first mirrors
tokamak
pulsed laser deposition
rhodium
tungsten
File in questo prodotto:
File Dimensione Formato  
prod_368359-doc_122078.pdf

accesso aperto

Descrizione: Articolo pubblicato
Tipologia: Versione Editoriale (PDF)
Dimensione 2.73 MB
Formato Adobe PDF
2.73 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/333610
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 17
social impact