Thin wall permeator tubes have been produced by diffusion welding of Pd-Ag foils. These dense metal membranes are proposed for separating and producing ultra-pure hydrogen as a result of their complete hydrogen selectivity. Furthermore, they present high hydrogen permeation fluxes as well as reduced costs on account of their reduced metal thickness. The reliability of these membrane tubes has been continuously tested during over 12 months of experimental campaign in presence of thermal and hydrogenation cycles. The permeability tests have been carried out measuring the hydrogen fluxes under controlled conditions of temperature and trans-membrane differential pressure. In particular, the behaviour of the membrane tube has been investigated in a wide range of temperatures (150-400 °C) and pressures (100-200 kPa) in order to simulate the use within permeators and membrane reactors where processes for producing hydrogen from hydrocarbons takes place. At temperature of 350-400 °C hydrogen permeability values around 1.0 × 10-8 mol m-1 s-1 Pa-0.5 have been measured and they are comparable with the literature data. A new mechanical design (finger-like configuration) of the membrane module has ensured the long life of the Pd-Ag permeator. The complete hydrogen selectivity of the membrane has been demonstrated by the tests.

Long term tests of Pd-Ag thin wall permeator tube

Basile A;Chiaravalloti F;
2006

Abstract

Thin wall permeator tubes have been produced by diffusion welding of Pd-Ag foils. These dense metal membranes are proposed for separating and producing ultra-pure hydrogen as a result of their complete hydrogen selectivity. Furthermore, they present high hydrogen permeation fluxes as well as reduced costs on account of their reduced metal thickness. The reliability of these membrane tubes has been continuously tested during over 12 months of experimental campaign in presence of thermal and hydrogenation cycles. The permeability tests have been carried out measuring the hydrogen fluxes under controlled conditions of temperature and trans-membrane differential pressure. In particular, the behaviour of the membrane tube has been investigated in a wide range of temperatures (150-400 °C) and pressures (100-200 kPa) in order to simulate the use within permeators and membrane reactors where processes for producing hydrogen from hydrocarbons takes place. At temperature of 350-400 °C hydrogen permeability values around 1.0 × 10-8 mol m-1 s-1 Pa-0.5 have been measured and they are comparable with the literature data. A new mechanical design (finger-like configuration) of the membrane module has ensured the long life of the Pd-Ag permeator. The complete hydrogen selectivity of the membrane has been demonstrated by the tests.
2006
Istituto per la Tecnologia delle Membrane - ITM
Hydrogen
Pd membrane
Long-term test
File in questo prodotto:
File Dimensione Formato  
prod_54855-doc_509.pdf

accesso aperto

Descrizione: Long term tests of Pd-Ag thin wall permeator tube
Tipologia: Versione Editoriale (PDF)
Dimensione 207.58 kB
Formato Adobe PDF
207.58 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/34922
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact