JT-60SA will complement ITER in resolving key issues to finally decide an acceptable DEMO design. Diagnostics play a key role in this mission. The electron temperature and density profiles are measured by a core and an edge Thomson scattering (TS) diagnostics with high spatial resolution, needed to identify the pedestal parameters and small profile structures. The two systems use a common tangential Nd:YAG laser beam path in the plasma equatorial plane. The collection optics for the edge system (low field side) is hosted in a lower oblique port and that for the coresystem in a horizontal port. The optics fit in the port plug tube and image the scattering volumes into an array of fiber bundles. They both are exposed to a high neutron dose of1016n/cm2over 13years of operation. The optics are supported by a mechanical structure decoupled from the cryostat.A set of filter polychromators with avalanche photodiode (APD) detectors spectrally analyze the scattered radiation. The development of the TS systems is carried out by a joint Japan-EU team.The conceptual design of the edge TS system is presented here. Simulations of the TS signals show acceptable accuracy down to1×1019m-3electron density, sufficient to measure the edge gradient and even a small region outside the separatrix.

Conceptual design of JT-60SA edge Thomson scattering diagnostic

Pasqualotto R;Nardino V;Pelli S;Raimondi V;Ricciarini S;Sozzi C
2020

Abstract

JT-60SA will complement ITER in resolving key issues to finally decide an acceptable DEMO design. Diagnostics play a key role in this mission. The electron temperature and density profiles are measured by a core and an edge Thomson scattering (TS) diagnostics with high spatial resolution, needed to identify the pedestal parameters and small profile structures. The two systems use a common tangential Nd:YAG laser beam path in the plasma equatorial plane. The collection optics for the edge system (low field side) is hosted in a lower oblique port and that for the coresystem in a horizontal port. The optics fit in the port plug tube and image the scattering volumes into an array of fiber bundles. They both are exposed to a high neutron dose of1016n/cm2over 13years of operation. The optics are supported by a mechanical structure decoupled from the cryostat.A set of filter polychromators with avalanche photodiode (APD) detectors spectrally analyze the scattered radiation. The development of the TS systems is carried out by a joint Japan-EU team.The conceptual design of the edge TS system is presented here. Simulations of the TS signals show acceptable accuracy down to1×1019m-3electron density, sufficient to measure the edge gradient and even a small region outside the separatrix.
2020
Istituto di Fisica Applicata - IFAC
Istituto per la Scienza e Tecnologia dei Plasmi - ISTP
Plasma diagnostics - interferometry
spectroscopy and imaging
Optics
Photon de-tectors for UV
visible and IR photons (solid-state) (PIN diodes
APDs
Si-PMTs
G-APDs
CCDs
EBCCDs
EMCCDs
CMOS imagers
etc)
Spectrometers
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/362556
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? ND
social impact