The results of the free-field calibration of an autonomous underwater noise recorder performed in an open-water test site are presented, as part of the output of the "UNAC-LOW" metrology research project which aimed at developing low-frequency calibration methods for hydrophones and autonomous recorders. The calibration was done for frequencies ranging from 200 Hz to 2 kHz by comparison with a reference hydrophone which was calibrated by another project partner using a closed-chamber pressure method. Calibration uncertainties were between 0.7 dB and 1.7 dB, and good agreement up to about 550 Hz was found with results obtained by another project partner using a different setup. Two different mooring solutions are presented and discussed for the device under test. Possible ways to extend the low frequency limit are discussed, to comply with requirements set in current EU regulation for monitoring of low-frequency continuous underwater noise.

Open-water free-field calibration of an autonomous underwater noise recorder for frequencies below 1 kHz

Salvatore Mauro;Silvano Buogo;
2019

Abstract

The results of the free-field calibration of an autonomous underwater noise recorder performed in an open-water test site are presented, as part of the output of the "UNAC-LOW" metrology research project which aimed at developing low-frequency calibration methods for hydrophones and autonomous recorders. The calibration was done for frequencies ranging from 200 Hz to 2 kHz by comparison with a reference hydrophone which was calibrated by another project partner using a closed-chamber pressure method. Calibration uncertainties were between 0.7 dB and 1.7 dB, and good agreement up to about 550 Hz was found with results obtained by another project partner using a different setup. Two different mooring solutions are presented and discussed for the device under test. Possible ways to extend the low frequency limit are discussed, to comply with requirements set in current EU regulation for monitoring of low-frequency continuous underwater noise.
2019
Istituto di iNgegneria del Mare - INM (ex INSEAN)
Inglese
Atti di convegni
2019 IMEKO TC-19 International Workshop on Metrology for the Sea
6
http://www.metrosea.org/ms2019/home
IMEKO-International Measurement Federation Secretariat
Budapest
UNGHERIA
Sì, ma tipo non specificato
03-05 Ottobre 2019
Genova
Metrology
Underwater noise
low frequency
3
open
Mauro, Salvatore; Buogo, Silvano; Fabrizio Borsani, Junio
273
info:eu-repo/semantics/conferenceObject
04 Contributo in convegno::04.01 Contributo in Atti di convegno
File in questo prodotto:
File Dimensione Formato  
prod_416710-doc_146875.pdf

accesso aperto

Descrizione: Open-water free-field calibration of an autonomous underwater noise recorder for frequencies below 1 kHz
Tipologia: Versione Editoriale (PDF)
Licenza: Dominio pubblico
Dimensione 313.11 kB
Formato Adobe PDF
313.11 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/366548
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact