The scope of the work is to determine the dependence of the reflection coefficient R (for W with projectiles of Ne) as the incident angle varies at moderate -low roughness with the attempt to have a confirmation of the experimental data by the simulated results so that the work in the present report focused mainly on the simulation of the reflected ions by a rough surface with a constant aspect ratio.

An investigation on the reflection coefficient of tungsten for Ne projectiles at different incident angles with the Kalypso MD software

F Ghezzi;L De Vecchi;M Pedroni;F Dell'Era;D Dellasega;S Pietralunga
2019

Abstract

The scope of the work is to determine the dependence of the reflection coefficient R (for W with projectiles of Ne) as the incident angle varies at moderate -low roughness with the attempt to have a confirmation of the experimental data by the simulated results so that the work in the present report focused mainly on the simulation of the reflected ions by a rough surface with a constant aspect ratio.
2019
Istituto di fisica del plasma - IFP - Sede Milano
Istituto di fotonica e nanotecnologie - IFN
Istituto per la Scienza e Tecnologia dei Plasmi - ISTP
Molecular dynamics; Tungsten; Reflection coefficient
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/366739
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact