The scope of the work is to determine the dependence of the reflection coefficient R (for W with projectiles of Ne) as the incident angle varies at moderate -low roughness with the attempt to have a confirmation of the experimental data by the simulated results so that the work in the present report focused mainly on the simulation of the reflected ions by a rough surface with a constant aspect ratio.

An investigation on the reflection coefficient of tungsten for Ne projectiles at different incident angles with the Kalypso MD software

F Ghezzi;L De Vecchi;EVassallo;M Pedroni;F Dell'Era;D Dellasega;S Pietralunga
2019

Abstract

The scope of the work is to determine the dependence of the reflection coefficient R (for W with projectiles of Ne) as the incident angle varies at moderate -low roughness with the attempt to have a confirmation of the experimental data by the simulated results so that the work in the present report focused mainly on the simulation of the reflected ions by a rough surface with a constant aspect ratio.
2019
Istituto di fisica del plasma - IFP - Sede Milano
Istituto di fotonica e nanotecnologie - IFN
Istituto per la Scienza e Tecnologia dei Plasmi - ISTP
Molecular dynamics; Tungsten; Reflection coefficient