Due to their interesting ferroelectric, conductive and dielectric properties, in recent years, perovskite-structured materials have begun to attract increasing interest in the biosensing field. In this study, a strontium titanate perovskite layer (SrTiO3) has been synthesized on a platinum electrode and exploited for the development of an impedimetric label-free immunosensor for Escherichia coli O157: H7 detection. The electrochemical characterization of the perovskite-modified electrode during the construction of the immunosensor, as well as after the interaction with different E. coli O157: H7 concentrations, showed a reproducible decrease of the total capacitance of the system that was used for the analytical characterization of the immunosensor. Under optimized conditions, the capacitive immunosensor showed a linear relationship from to 1 to 7 log cfu/mL with a low detection limit of 1 log cfu/mL. Moreover, the atomic force microscopy (AFM) technique underlined the increase in roughness of the SrTiO3-modified electrode surface after antibody immobilization, as well as the effective presence of cells with the typical size of E. coli.

Fabrication of SrTiO3 Layer on Pt Electrode for Label-Free Capacitive Biosensors

Orgiani Pasquale;Pilloton Roberto;
2018

Abstract

Due to their interesting ferroelectric, conductive and dielectric properties, in recent years, perovskite-structured materials have begun to attract increasing interest in the biosensing field. In this study, a strontium titanate perovskite layer (SrTiO3) has been synthesized on a platinum electrode and exploited for the development of an impedimetric label-free immunosensor for Escherichia coli O157: H7 detection. The electrochemical characterization of the perovskite-modified electrode during the construction of the immunosensor, as well as after the interaction with different E. coli O157: H7 concentrations, showed a reproducible decrease of the total capacitance of the system that was used for the analytical characterization of the immunosensor. Under optimized conditions, the capacitive immunosensor showed a linear relationship from to 1 to 7 log cfu/mL with a low detection limit of 1 log cfu/mL. Moreover, the atomic force microscopy (AFM) technique underlined the increase in roughness of the SrTiO3-modified electrode surface after antibody immobilization, as well as the effective presence of cells with the typical size of E. coli.
2018
Istituto di Cristallografia - IC
Inglese
8
1
26
36
11
Sì, ma tipo non specificato
biosensors
label-free
perovskite
strontium titanium oxide
Fabrication of SrTiO3 Layer on Pt Electrode for Label-Free Capacitive Biosensors by Francesca Malvano, Luigi Maritato, Giovanni Carapella, Pasquale Orgiani, Roberto Pilloton, Marisa Di Matteo and Donatella Albanese Biosensors 2018, 8(1), 26; https://doi.org/10.3390/bios8010026 Received: 22 February 2018 / Revised: 9 March 2018 / Accepted: 13 March 2018 / Published: 16 March 2018
7
info:eu-repo/semantics/article
262
Malvano, Francesca; Maritato, Luigi; Carapella, Giovanni; Orgiani, Pasquale; Pilloton, Roberto; Di Matteo, Marisa; Albanese, Donatella
01 Contributo su Rivista::01.01 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/371045
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 15
social impact