Aim of this in vitro study was to analyze structural properties of two different polymeric orthodontic aligners, Exceed30 (EX30) and Smart Track (LD30), before and after use. Forty patterns of aligners were randomly selected: 20 LD30 and 20 EX30, worn intra-orally for 14±3 days, 22 h/day. From each aligner, 10 specimens were prepared from buccal surfaces of the incisor region by the cutting of samples 5×5 mm under a stereomicroscope. All samples were subjected to Fourier Transform Infrared Spectroscopy, micro-Raman spectroscopy, X-ray diffraction, Tensile and Indentation strength test. LD30 appeared more homogeneous, with a crystalline fraction lower than EX30 and exhibited a higher elastic behavior and a lower tendency to warp after use than EX30. LD30 demonstrated better adaptability to the dental arch and greater consistency of application of orthodontic forces than produced with EX30. However, both materials showed structural modifi cations that resulted in increased sample hardness and hyper-plasticity.

Mechanical properties of "two generations" of teeth aligners: Change analysis during oral permanence

Luca PAZZINI;Alessandro PECORA;Valentina MUSSI;Luca MAIOLO
2018

Abstract

Aim of this in vitro study was to analyze structural properties of two different polymeric orthodontic aligners, Exceed30 (EX30) and Smart Track (LD30), before and after use. Forty patterns of aligners were randomly selected: 20 LD30 and 20 EX30, worn intra-orally for 14±3 days, 22 h/day. From each aligner, 10 specimens were prepared from buccal surfaces of the incisor region by the cutting of samples 5×5 mm under a stereomicroscope. All samples were subjected to Fourier Transform Infrared Spectroscopy, micro-Raman spectroscopy, X-ray diffraction, Tensile and Indentation strength test. LD30 appeared more homogeneous, with a crystalline fraction lower than EX30 and exhibited a higher elastic behavior and a lower tendency to warp after use than EX30. LD30 demonstrated better adaptability to the dental arch and greater consistency of application of orthodontic forces than produced with EX30. However, both materials showed structural modifi cations that resulted in increased sample hardness and hyper-plasticity.
2018
Istituto per la Microelettronica e Microsistemi - IMM
Istituto dei Sistemi Complessi - ISC
Invisalign®
Indentation and tensile strength test
Fourier transform infrared spectroscopy
Micro-Raman spectroscopy
X-ray diffraction
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/374544
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact