This review summarises the use of the Ankom DaisyII incubator (ADII; Ankom Technology Corporation Fairport, NY, USA), as presented in studies on digestibility, and its extension to other species apart from ruminants, from its introduction until today. This technique has been modified and adapted to allow for different types of investigations to be conducted. Researchers have studied and tested different procedures, and the main sources of variation have been found to be: the inoculum source, sample size, sample preparation, and bag type. In vitro digestibility methods, applied to the ADII incubator, have been reviewed, the precision and accuracy of the method using the ADII incubator have been dealt with, and comparisons with other methods have been made. Moreover, some hypotheses on the possible evolutions of this technology in non-ruminants, including pets, have been described. To date, there are no standardised protocols for the collection, storage, and transportation of rumen fluid or faeces. There is also still a need to standardise the procedures for washing the bags after digestion. Moreover, some performance metrics of the instrument (such as the reliability of the rotation mechanism of the jars) still require improvement.

In vitro techniques using the DaisyII incubator for assessment of digestibility: A review

PEIRETTI PG
2020

Abstract

This review summarises the use of the Ankom DaisyII incubator (ADII; Ankom Technology Corporation Fairport, NY, USA), as presented in studies on digestibility, and its extension to other species apart from ruminants, from its introduction until today. This technique has been modified and adapted to allow for different types of investigations to be conducted. Researchers have studied and tested different procedures, and the main sources of variation have been found to be: the inoculum source, sample size, sample preparation, and bag type. In vitro digestibility methods, applied to the ADII incubator, have been reviewed, the precision and accuracy of the method using the ADII incubator have been dealt with, and comparisons with other methods have been made. Moreover, some hypotheses on the possible evolutions of this technology in non-ruminants, including pets, have been described. To date, there are no standardised protocols for the collection, storage, and transportation of rumen fluid or faeces. There is also still a need to standardise the procedures for washing the bags after digestion. Moreover, some performance metrics of the instrument (such as the reliability of the rotation mechanism of the jars) still require improvement.
2020
Istituto di Scienze delle Produzioni Alimentari - ISPA
in vitro digestibility
inoculum
rumen fluid
faeces
enzyme
Ankom DaisyII incubator
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/410884
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 36
  • ???jsp.display-item.citation.isi??? ND
social impact