An investigation of the mechanical behaviour of CLT shearwalls, where either door or window openings are cut out of the panel, is undertaken. The main aim of the study is to investigate failure modes related to either mechanical anchor or CLT panel, based on the geometrical dimensions and mechanical properties of shearwall. The results of six full-scale monolithic CLT shearwalls with window or door openings are presented and discussed. The results obtained from the full-scale shearwall tests are used to validate a proposed numerical model, where input parameters, such as the mechanical properties of the CLT panels and mechanical anchors, are obtained from component level tests on beams and connections in isolation. The study shows that differently from single-panel shearwalls with no openings, brittle failure in the CLT panels is a possible mode of failure, which needs to be considered in design. The failure mode in the CLT panels is observed to occur either in bending or net shear in the lintel beams. The proposed numerical procedure is found capable of estimating the maximum load with reasonable accuracy, and the model predictions of the failure mode, number of centre of rotations, and the overall deformation of the CLT panel are accurate for all the studied specimens.

Experimental and numerical study on the mechanical behaviour of CLT shearwalls with openings

Casagrande D;Fanti R;Polastri A
2021

Abstract

An investigation of the mechanical behaviour of CLT shearwalls, where either door or window openings are cut out of the panel, is undertaken. The main aim of the study is to investigate failure modes related to either mechanical anchor or CLT panel, based on the geometrical dimensions and mechanical properties of shearwall. The results of six full-scale monolithic CLT shearwalls with window or door openings are presented and discussed. The results obtained from the full-scale shearwall tests are used to validate a proposed numerical model, where input parameters, such as the mechanical properties of the CLT panels and mechanical anchors, are obtained from component level tests on beams and connections in isolation. The study shows that differently from single-panel shearwalls with no openings, brittle failure in the CLT panels is a possible mode of failure, which needs to be considered in design. The failure mode in the CLT panels is observed to occur either in bending or net shear in the lintel beams. The proposed numerical procedure is found capable of estimating the maximum load with reasonable accuracy, and the model predictions of the failure mode, number of centre of rotations, and the overall deformation of the CLT panel are accurate for all the studied specimens.
2021
Istituto per la BioEconomia - IBE
Shearwalls
Openings
Timber structures
Numerical models
Beam tests
Cross laminated timber
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/417469
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? ND
social impact