This article investigates the feasibility of using a simplified approach, based on the measurement of power ratio parameters, for harmonic emissions assessment at the point of common coupling (PCC). The proposed approach comes from the common concept of power factor correction and the definitions of the IEEE Std. 1459-2010, where line utilization and harmonic pollution levels are evaluated by means of ratios between the power quantities of the apparent power decomposition. In addition to the IEEE Std. 1459-2010 indicators, in this article, the behavior is studied of additional parameters that are conceptually similar to those defined by the IEEE Std. 1459-2010. The suitability of such parameters is discussed, for both single- and three-phase balanced/unbalanced cases, taking into account both their behavior in different scenarios and their effectiveness when the measurement uncertainty is taken into account. The study is supported by some simulation results that have been obtained on an IEEE benchmark power system, which allows reproducing linear and nonlinear load conditions, balanced and unbalanced operating conditions, and the presence of capacitors for power factor correction.

Measurement of Simplified Single- And Three-Phase Parameters for Harmonic Emission Assessment Based on IEEE 1459-2010

Guaiana S;Di Cara D;Panzavecchia N;Tinè G
2020

Abstract

This article investigates the feasibility of using a simplified approach, based on the measurement of power ratio parameters, for harmonic emissions assessment at the point of common coupling (PCC). The proposed approach comes from the common concept of power factor correction and the definitions of the IEEE Std. 1459-2010, where line utilization and harmonic pollution levels are evaluated by means of ratios between the power quantities of the apparent power decomposition. In addition to the IEEE Std. 1459-2010 indicators, in this article, the behavior is studied of additional parameters that are conceptually similar to those defined by the IEEE Std. 1459-2010. The suitability of such parameters is discussed, for both single- and three-phase balanced/unbalanced cases, taking into account both their behavior in different scenarios and their effectiveness when the measurement uncertainty is taken into account. The study is supported by some simulation results that have been obtained on an IEEE benchmark power system, which allows reproducing linear and nonlinear load conditions, balanced and unbalanced operating conditions, and the presence of capacitors for power factor correction.
2020
Istituto di iNgegneria del Mare - INM (ex INSEAN)
harmonic distortion
harmonic analysis
power measurement
power quality
parameter estimation
uncertainty analysis
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/423841
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 15
  • ???jsp.display-item.citation.isi??? ND
social impact