RFX-mod2 is an upgrade of RFX-mod that will use a modified shell and mechanical structure in order to enhance plasma-shell proximity and therefore to improve plasma control. The Control and Data Acquisition System for most of the plant systems and diagnostics previously used in RFX-mod will be refurbished, while others will be completely re-built. The most important component that will be completely renewed is the ElectroMagnetic probe (EM) data acquisition system, where a new architecture based on XILINX Zynq FPGA will be used to carry out at the same time both high-speed data acquisition and resampled data streaming for active plasma control. The use of MDSplus will be retained in RFX-mod2, while the MARTe framework used for real-time plasma control will be replaced by MARTe2, a new framework developed under strict software quality standards. Plant control in RFX-mod2 will be supervised by WinCC-OA, replacing the previous FactoryLink SCADA systems. Older plant systems such as vacuum control based on outdated S5 PLCs will be updated and will use OPC-UA for communication with the supervisory control system.

The upgrade of the control and data acquisition system of RFXMod2

Manduchi G;Luchetta A;Taliercio C;Barbato P;Capobianco R;Moressa M;Simionato P;Zampiva E
2021

Abstract

RFX-mod2 is an upgrade of RFX-mod that will use a modified shell and mechanical structure in order to enhance plasma-shell proximity and therefore to improve plasma control. The Control and Data Acquisition System for most of the plant systems and diagnostics previously used in RFX-mod will be refurbished, while others will be completely re-built. The most important component that will be completely renewed is the ElectroMagnetic probe (EM) data acquisition system, where a new architecture based on XILINX Zynq FPGA will be used to carry out at the same time both high-speed data acquisition and resampled data streaming for active plasma control. The use of MDSplus will be retained in RFX-mod2, while the MARTe framework used for real-time plasma control will be replaced by MARTe2, a new framework developed under strict software quality standards. Plant control in RFX-mod2 will be supervised by WinCC-OA, replacing the previous FactoryLink SCADA systems. Older plant systems such as vacuum control based on outdated S5 PLCs will be updated and will use OPC-UA for communication with the supervisory control system.
2021
Istituto per la Scienza e Tecnologia dei Plasmi - ISTP
Inglese
167
112329-1
112329-5
5
https://www.sciencedirect.com/science/article/pii/S0920379621001058?casa_token=HMDL7jUF98MAAAAA:epnONYeGZEkxGhmCjJ8QFFqniz3sCPF0dhEPTwQZeFxWftuLqkoJjdazmCjuMvrYrL0BNXCrXw
Sì, ma tipo non specificato
Data ac
Plasma control
MDSPlus
MARTe
Article Number: 112329 - Electronic ISSN: 1873-7196 - http://www.scopus.com/inward/record.url?eid=2-s2.0-85101359809&partnerID=q2rCbXpz
14
info:eu-repo/semantics/article
262
Manduchi, G; Luchetta, A; Taliercio, C; Rigoni, A; Martini, G; Cavazzana, R; Ferron, N; Barbato, P; Breda, M; Capobianco, R; Molon, F; Moressa, M; Sim...espandi
01 Contributo su Rivista::01.01 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/425195
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 6
social impact