An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure forCROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied depending on the size of phonon NTD-Ge sensors glued to both LMO and Ge absorbers, shape of the Ge light detectors (circular vs. square, from two suppliers), in different light collection conditions (with and without reflector, with aluminum coated LMO crystal surface). The scintillating bolometer array was operated over 8 months in the low-background conditions that allowed to probe a very low, ?Bq/kg, level of the LMO crystals radioactive contamination by 228Th and 226Ra.

Twelve-crystal prototype of Li2MoO4 scintillating bolometers for CUPID and CROSS experiments

Bettelli M;Boldrini V;Colantoni I;Mancarella F;Rizzoli R;
2023

Abstract

An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure forCROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied depending on the size of phonon NTD-Ge sensors glued to both LMO and Ge absorbers, shape of the Ge light detectors (circular vs. square, from two suppliers), in different light collection conditions (with and without reflector, with aluminum coated LMO crystal surface). The scintillating bolometer array was operated over 8 months in the low-background conditions that allowed to probe a very low, ?Bq/kg, level of the LMO crystals radioactive contamination by 228Th and 226Ra.
2023
Istituto dei Materiali per l'Elettronica ed il Magnetismo - IMEM
Istituto per la Microelettronica e Microsistemi - IMM
Istituto di Nanotecnologia - NANOTEC
Cryogenic detectors, Double-beta decay detectors, Particle identification methods, Scintillators, scintillation and light emission processes
File in questo prodotto:
File Dimensione Formato  
Twelve-crystal prototype of Li2MoO4 scintillating bolometers for CUPID and CROSS experiments.pdf

accesso aperto

Descrizione: Articolo
Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 7.32 MB
Formato Adobe PDF
7.32 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/450944
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact