Cross-Laminated Timber (CLT) shear-walls composed of multiple panels are nowadays a viable alter¬native to single-panel CLT walls in mid-rise construction sector. Prefabrication process, transport and erection limits are some of the reasons why short panels, vertically-jointed by means of mechanical fasteners, are preferred to CLT single-panel walls. When a significant amount of energy dissipation in the vertical joint is not required (i.e. low seismic prone areas), stiff vertical joints are preferred: the wall behaves mostly like a single-panel wall and vertical joints are designed to minimize the relative displacement between the panels. This paper presents an experimental campaign on aluminium stiff shear-key connector, as an alternative to traditional screwed connections for stiff vertical joints in multi- panels CLT walls. Monotonic tests were performed on shear-key connectors and full-scale tests on multi-panel CLT shear-walls were carried out. A numerical model was developed in order to extend the experimental results on full-scale tests by means of a sensitivity analysis.

Experimental characterization of stiff aluminium connectors for multi-panel CLT shear-walls

Rigo P;Polastri A;Casagrande D;
2023

Abstract

Cross-Laminated Timber (CLT) shear-walls composed of multiple panels are nowadays a viable alter¬native to single-panel CLT walls in mid-rise construction sector. Prefabrication process, transport and erection limits are some of the reasons why short panels, vertically-jointed by means of mechanical fasteners, are preferred to CLT single-panel walls. When a significant amount of energy dissipation in the vertical joint is not required (i.e. low seismic prone areas), stiff vertical joints are preferred: the wall behaves mostly like a single-panel wall and vertical joints are designed to minimize the relative displacement between the panels. This paper presents an experimental campaign on aluminium stiff shear-key connector, as an alternative to traditional screwed connections for stiff vertical joints in multi- panels CLT walls. Monotonic tests were performed on shear-key connectors and full-scale tests on multi-panel CLT shear-walls were carried out. A numerical model was developed in order to extend the experimental results on full-scale tests by means of a sensitivity analysis.
2023
Istituto per la BioEconomia - IBE
Cross-laminated timber
Multi-panel
shear walls
Shear-key connectors
Hold-down
Vertical joints
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/451133
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact