In this paper, we report on the validation of an autonomous drone-based delivery system equipped with a smart capsule for the transportation of blood products in urban areas. The influence of some thermo-mechanical parameters, such as altitude, acceleration/deceleration, external temperature and humidity, on the specimens' integrity were analyzed. The comparison of the results carried out by hemolytic tests, performed systematically on samples before and after each drone flight, clearly demonstrated that the integrity of blood is preserved and no adverse effects took place during the transport; these results can be addressed to the smart-capsule properties, which allows integrating real-time quality monitoring and control of the temperature experienced by blood products and mechanical vibrations. In addition, we demonstrated this transport system reduces the delivery time considerably. A risk analysis (i.e., HFMEA) was applied to all delivery processes to assess possible criticalities. To the best of our knowledge, this is the first time a drone-based delivery system of blood products in an urban area has been validated to be employed in a future clinical scenario.

Preliminary Clinical Validation of a Drone-Based Delivery System in Urban Scenarios Using a Smart Capsule for Blood

Pirri Angela
;
2022

Abstract

In this paper, we report on the validation of an autonomous drone-based delivery system equipped with a smart capsule for the transportation of blood products in urban areas. The influence of some thermo-mechanical parameters, such as altitude, acceleration/deceleration, external temperature and humidity, on the specimens' integrity were analyzed. The comparison of the results carried out by hemolytic tests, performed systematically on samples before and after each drone flight, clearly demonstrated that the integrity of blood is preserved and no adverse effects took place during the transport; these results can be addressed to the smart-capsule properties, which allows integrating real-time quality monitoring and control of the temperature experienced by blood products and mechanical vibrations. In addition, we demonstrated this transport system reduces the delivery time considerably. A risk analysis (i.e., HFMEA) was applied to all delivery processes to assess possible criticalities. To the best of our knowledge, this is the first time a drone-based delivery system of blood products in an urban area has been validated to be employed in a future clinical scenario.
2022
Istituto di Fisica Applicata - IFAC
smart capsule
artificial intelligence
drones
blood products
drone transport
risk analysis
HFMEA method
File in questo prodotto:
File Dimensione Formato  
drones-06-00195-v2.pdf

accesso aperto

Licenza: Creative commons
Dimensione 1.86 MB
Formato Adobe PDF
1.86 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/460293
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? ND
social impact