The objective of this study was to determine the total glucosinolate (GLS) content in Camelina sativa, using a simple and sensitive method, based on the colorimetric reaction of sodium tetrachloropalladate (II) with GLSs, and to quantify them by spectrophotometry without the use of HPLC. Glucosinolates from defatted meal, seeds, animal feeds and sprouts were extracted and isolated using a weak anion exchange column. Sodium tetrachloropalladate (II) solution was added to the extract and the absorbance measured at 420 nm. The repeatability (intra-assay) of the sodium tetrachloropalladate (II)—assay (Pd-assay) was very high, with CVs ranging from 2.07 to 0.90% for the single experiments. The inter-assay was also very high, displayed by a CV of 1.65% across all of the experiments. The Pd-assay is therefore able to quantify GLS amounts with good accuracy in all the tested matrices, which cover a very wide range from 0.50 µmol g−1 DW in animal feed to about 40 µmol g−1 DW in defatted meal. The good agreement between the Pd-assay and HPLC was testified by a significant correlation R2 = 0.9937. These results indicate that the accuracy and repeatability of the Pd-assay are suitable for measuring total GLS in all camelina tissues tested.

Spectrophotometric Determination of Total Glucosinolate Content in Different Tissues of Camelina sativa (L.) Crantz

Incoronata Galasso
;
Angela Rosa Piergiovanni;Elena Ponzoni;Ida Melania Brambilla
2024

Abstract

The objective of this study was to determine the total glucosinolate (GLS) content in Camelina sativa, using a simple and sensitive method, based on the colorimetric reaction of sodium tetrachloropalladate (II) with GLSs, and to quantify them by spectrophotometry without the use of HPLC. Glucosinolates from defatted meal, seeds, animal feeds and sprouts were extracted and isolated using a weak anion exchange column. Sodium tetrachloropalladate (II) solution was added to the extract and the absorbance measured at 420 nm. The repeatability (intra-assay) of the sodium tetrachloropalladate (II)—assay (Pd-assay) was very high, with CVs ranging from 2.07 to 0.90% for the single experiments. The inter-assay was also very high, displayed by a CV of 1.65% across all of the experiments. The Pd-assay is therefore able to quantify GLS amounts with good accuracy in all the tested matrices, which cover a very wide range from 0.50 µmol g−1 DW in animal feed to about 40 µmol g−1 DW in defatted meal. The good agreement between the Pd-assay and HPLC was testified by a significant correlation R2 = 0.9937. These results indicate that the accuracy and repeatability of the Pd-assay are suitable for measuring total GLS in all camelina tissues tested.
2024
Istituto di biologia e biotecnologia agraria (IBBA)
Istituto di Bioscienze e Biorisorse - IBBR
Glucosinolates, Sodium tetrachloropalladate II, Seed, Defatted meal, Sprouts
File in questo prodotto:
File Dimensione Formato  
2024-Galasso et al.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 1.22 MB
Formato Adobe PDF
1.22 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/519609
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact