Reflection mode scanning microwave microscopy (SMM) is compared to a newly developed transmission mode imaging hardware for extended scattering S11 and S12 measurements. Transmission mode imaging is realized by an SMA connector placed below the sample to excite an electromagnetic wave towards the cantilever acting as nanoscale-sized receiver structure. The frequency response was investigated between 1-20 GHz and a circuitry model of the SMM matching network was combined with a 3D finite element model of the tip-sample system. Modeling results include the local 3D electric field distribution around the nanoscale cantilever tip in contact to the sample. Reflection mode measurements were calibrated using a simple three error-parameter workflow allowing for quantitative impedance and capacitance imaging. A qualitative agreement was obtained between measurements and SMM models for both S11 and S12.

Transmission and reflection mode scanning microwave microscopy (SMM): Experiments, calibration, and simulations

Lucibello, A.;Proietti, E.;Marcelli, R.;
2015

Abstract

Reflection mode scanning microwave microscopy (SMM) is compared to a newly developed transmission mode imaging hardware for extended scattering S11 and S12 measurements. Transmission mode imaging is realized by an SMA connector placed below the sample to excite an electromagnetic wave towards the cantilever acting as nanoscale-sized receiver structure. The frequency response was investigated between 1-20 GHz and a circuitry model of the SMM matching network was combined with a 3D finite element model of the tip-sample system. Modeling results include the local 3D electric field distribution around the nanoscale cantilever tip in contact to the sample. Reflection mode measurements were calibrated using a simple three error-parameter workflow allowing for quantitative impedance and capacitance imaging. A qualitative agreement was obtained between measurements and SMM models for both S11 and S12.
2015
Istituto per la Microelettronica e Microsistemi - IMM - Sede Secondaria Roma
microwave
nanoscale
scanning microwave microscopy
transmission
File in questo prodotto:
File Dimensione Formato  
Transmission_and_reflection_mode_scanning_microwave_microscopy_SMM_Experiments_calibration_and_simulations.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.49 MB
Formato Adobe PDF
1.49 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/525116
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? ND
social impact