: The development of molecules that interact with G-quadruplex (G4) sequences requires effective evaluation methods. Several techniques are currently available, including nuclear magnetic resonance (NMR) spectroscopy and X-ray crystallography, surface plasmon resonance (SPR), isothermal titration calorimetry (ITC) and mass spectrometry (MS), fluorescence using FRET-melting, G4-fluorescent intercalator displacement assay (G4-FID) and affinity chromatography. Among these, CD spectroscopy is gaining prominence due to its lower material requirements, faster experimentation and quicker data processing. However, conventional CD methods have limitations, such as higher sample volume required and the inability to handle high-throughput analysis efficiently. The use of synchrotron radiation in high-throughput analysis methods (HT-SRCD) has further advanced the investigation of small-molecule interactions with DNA G4 structures in the presence of various monovalent cations. HT-SRCD offers the capability to analyze multiple samples simultaneously, overcoming the limitations of conventional CD methods. To validate this approach, three biologically relevant G4 sequences-HTelo1, G3T3 and T95-2T-were investigated. Their interactions with a library of small tetrazole-based molecules, synthesized via a four-component Ugi reaction, and with a peptide sequence deriving from RHAU helicases (Rhau25), were evaluated. The results demonstrate that this method not only effectively discriminates between different ligands but also provides valuable insights into the selectivity and the modes of interaction of these ligands with the G4 sequences.
Rapid G4 Ligand Screening Through Spectral Changes Using HT-SRCD with Minimal Material
Claudia Honisch;Pietro Spanu;Fausta Ulgheri;Giovanni Loriga;Andrea Beccu;Barbara Biondi;Paolo Ruzza;
2025
Abstract
: The development of molecules that interact with G-quadruplex (G4) sequences requires effective evaluation methods. Several techniques are currently available, including nuclear magnetic resonance (NMR) spectroscopy and X-ray crystallography, surface plasmon resonance (SPR), isothermal titration calorimetry (ITC) and mass spectrometry (MS), fluorescence using FRET-melting, G4-fluorescent intercalator displacement assay (G4-FID) and affinity chromatography. Among these, CD spectroscopy is gaining prominence due to its lower material requirements, faster experimentation and quicker data processing. However, conventional CD methods have limitations, such as higher sample volume required and the inability to handle high-throughput analysis efficiently. The use of synchrotron radiation in high-throughput analysis methods (HT-SRCD) has further advanced the investigation of small-molecule interactions with DNA G4 structures in the presence of various monovalent cations. HT-SRCD offers the capability to analyze multiple samples simultaneously, overcoming the limitations of conventional CD methods. To validate this approach, three biologically relevant G4 sequences-HTelo1, G3T3 and T95-2T-were investigated. Their interactions with a library of small tetrazole-based molecules, synthesized via a four-component Ugi reaction, and with a peptide sequence deriving from RHAU helicases (Rhau25), were evaluated. The results demonstrate that this method not only effectively discriminates between different ligands but also provides valuable insights into the selectivity and the modes of interaction of these ligands with the G4 sequences.| File | Dimensione | Formato | |
|---|---|---|---|
|
molecules-30-03322.pdf
accesso aperto
Descrizione: Rapid G4 Ligand Screening Through Spectral Changes Using HT-SRCD with Minimal Material
Tipologia:
Versione Editoriale (PDF)
Licenza:
Creative commons
Dimensione
9.13 MB
Formato
Adobe PDF
|
9.13 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.


