Carbon paste electrodes modified with conducting polymers for sensitive and selective determination of lead are presented. A novel method for generating a reproducible polymer-coated electrode surface is developed. We prove that 1,8-diaminonaphthalene (1,8-DAN) mixed with a carbon paste electrode leads to a conducting polymer in acidic medium while, in the same medium, this polymer is known to be non-conducting on platinum electrode. The electrode behaviour of poly(1,8-DAN), electropolymerised into carbon paste, was investigated by cyclic voltammetry in the presence of the ferri-ferrocyanide couple. A carbon paste electrode modified with poly(1,8-DAN) was used to determine Pb2+ in aqueous solutions. Pb2+ ions were firstly complexed and then electrochemically deposited by a potential step to -0.9 V. The accumulated lead after reduction was anodically stripped by differential pulse voltammetry. Different parameters, such as pH of the solution, preconcentration time, and electropolymerisation procedures were studied. For a preconcentration time of ten minutes, the calibration graph was linear from 40 to 2070 ng mL(-1) with r(2)=0.998. The detection limit was found to be 30 ng mL(-1), and the relative standard deviation was 6%.

Carbon paste electrode bulk modified with a conducting polymer poly(1,8-diaminonaphthalene): application to lead determination

Antonella Curulli;
2003

Abstract

Carbon paste electrodes modified with conducting polymers for sensitive and selective determination of lead are presented. A novel method for generating a reproducible polymer-coated electrode surface is developed. We prove that 1,8-diaminonaphthalene (1,8-DAN) mixed with a carbon paste electrode leads to a conducting polymer in acidic medium while, in the same medium, this polymer is known to be non-conducting on platinum electrode. The electrode behaviour of poly(1,8-DAN), electropolymerised into carbon paste, was investigated by cyclic voltammetry in the presence of the ferri-ferrocyanide couple. A carbon paste electrode modified with poly(1,8-DAN) was used to determine Pb2+ in aqueous solutions. Pb2+ ions were firstly complexed and then electrochemically deposited by a potential step to -0.9 V. The accumulated lead after reduction was anodically stripped by differential pulse voltammetry. Different parameters, such as pH of the solution, preconcentration time, and electropolymerisation procedures were studied. For a preconcentration time of ten minutes, the calibration graph was linear from 40 to 2070 ng mL(-1) with r(2)=0.998. The detection limit was found to be 30 ng mL(-1), and the relative standard deviation was 6%.
2003
Istituto per lo Studio dei Materiali Nanostrutturati - ISMN
electropolymerisation; poly(1
8-diaminonaphthalene); lead; carbon paste electrode
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/72663
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 68
  • ???jsp.display-item.citation.isi??? 63
social impact