A fluorescence polarization immunoassay previously described for deoxynivalenol (DON) screening in wheat was optimized for the rapid quantification of DON in durum wheat kernels, semolina, and pasta. A background signal was observed in both spiked and naturally contaminated samples, strictly depending on the testing matrix. After subtracting the background DON level for durum wheat (0.27 µg of DON per g), semolina (0.08 µg of DON per g), and pasta (0.04 µg of DON per g), an accurate quantification of DON was possible at levels greater than 0.10 µg/g for all matrices. Average recoveries from spiked samples (0.25 to 1.75 µg/g) were 98, 102, and 101% for wheat, semolina, and pasta, respectively. Comparative analyses of 35 naturally contaminated durum wheat samples, 22 semolina samples, and 26 pasta samples performed by both the fluorescence polarization method and high-pressure liquid chromatography/immunoaffinity cleanup showed a good correlation (r > 0.995). The fluorescence polarization method showed better accuracy and precision with respect to the high-pressure liquid chromatography method and is suitable for the rapid and quantitative determination of DON in durum wheat–based products at levels foreseen by existing or coming international regulations.

Optimization of a fluorescence polarization immunoassay for rapid quantification of deoxynivalenol in durum wheat based products

Lippolis V;Pascale M;Visconti A
2006

Abstract

A fluorescence polarization immunoassay previously described for deoxynivalenol (DON) screening in wheat was optimized for the rapid quantification of DON in durum wheat kernels, semolina, and pasta. A background signal was observed in both spiked and naturally contaminated samples, strictly depending on the testing matrix. After subtracting the background DON level for durum wheat (0.27 µg of DON per g), semolina (0.08 µg of DON per g), and pasta (0.04 µg of DON per g), an accurate quantification of DON was possible at levels greater than 0.10 µg/g for all matrices. Average recoveries from spiked samples (0.25 to 1.75 µg/g) were 98, 102, and 101% for wheat, semolina, and pasta, respectively. Comparative analyses of 35 naturally contaminated durum wheat samples, 22 semolina samples, and 26 pasta samples performed by both the fluorescence polarization method and high-pressure liquid chromatography/immunoaffinity cleanup showed a good correlation (r > 0.995). The fluorescence polarization method showed better accuracy and precision with respect to the high-pressure liquid chromatography method and is suitable for the rapid and quantitative determination of DON in durum wheat–based products at levels foreseen by existing or coming international regulations.
2006
Istituto di Scienze delle Produzioni Alimentari - ISPA
Fluorescence polarization immunoassay
deoxynivalenol
wheat
semolina
pasta
File in questo prodotto:
File Dimensione Formato  
prod_46111-doc_23781.pdf

solo utenti autorizzati

Descrizione: Optimization of a fluorescence polarization immunoassay for rapid quantification of deoxynivalenol in Durum wheat-based products
Dimensione 114.36 kB
Formato Adobe PDF
114.36 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/73643
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 53
social impact