A case study of multi-robot platform calibration is reported in the domain of robot-assisted neurosurgery. The robot system is composed of a hybrid parallel kinematic machine and 2 KUKA LWR arms and is dedicated to awake surgery with head motion compensation. The target accuracy is sub-millimeter. Calibration errors are known to cumulate along the kinematic loops in the system, so a method of volumetric compensation of inaccuracies is applied. Configuration-dependent compensation homogeneous transforms populate a look-up table trained offline for a set of discrete subregions of the workspace. At runtime, the compensation is applied to the robot motion so to reach an end-to-end static accuracy distributed with a median 0.75 mm and below 1 mm for the 95% of tests, with a 1:36 reduction factor from the default calibration conditions.

Analysis and compensation of calibration errors in a multi-robot surgical platform

Vicentini Federico;Molinari Tosatti Lorenzo
2015

Abstract

A case study of multi-robot platform calibration is reported in the domain of robot-assisted neurosurgery. The robot system is composed of a hybrid parallel kinematic machine and 2 KUKA LWR arms and is dedicated to awake surgery with head motion compensation. The target accuracy is sub-millimeter. Calibration errors are known to cumulate along the kinematic loops in the system, so a method of volumetric compensation of inaccuracies is applied. Configuration-dependent compensation homogeneous transforms populate a look-up table trained offline for a set of discrete subregions of the workspace. At runtime, the compensation is applied to the robot motion so to reach an end-to-end static accuracy distributed with a median 0.75 mm and below 1 mm for the 95% of tests, with a 1:36 reduction factor from the default calibration conditions.
2015
Istituto di Sistemi e Tecnologie Industriali Intelligenti per il Manifatturiero Avanzato - STIIMA (ex ITIA)
Inglese
IEEE/RSJ International Conference on Intelligent Robots and Systems 2015
3633
3640
8
9781479999941
http://www.scopus.com/record/display.url?eid=2-s2.0-84958154333&origin=inward
Sì, ma tipo non specificato
September 28 - October 02, 2015
Hamburg
Calibration
Iterative closest point algorithm
Kinematics
Manipulators
Robot sensing systems
Transforms
4
none
Vicentini, Federico; Magnoni, Paolo; Giussani, Matteo; MOLINARI TOSATTI, Lorenzo
273
info:eu-repo/semantics/conferenceObject
04 Contributo in convegno::04.01 Contributo in Atti di convegno
   Active Constraints Technologies for Ill-defined or Volatile Environments
   ACTIVE
   FP7
   270460
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/315696
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 2
social impact