This paper aims at assessing the influence of environmental parameters on the modal characteristics of age-old masonry constructions. The results of a long-term ambient vibration monitoring of the San Frediano bell tower in Lucca (Italy) are reported. The tower, dating back to the 11th century, has been fitted along its height with four triaxial seismometric stations, which were left active for about one year. Data from the monitoring system have been processed via the Stochastic Subspace Identification Method in order to identify the tower's modal characteristics and their variations over the year. The dependence of the tower's frequencies on the ambient temperature was first studied and simulated via simple auto-regressive models. Then, some output-only models based on the principal component analysis (PCA) were applied, under the hypotheses of both linear and nonlinear (Kernel PCA) dependence of the natural frequencies on the unknown environmental parameters. The results indicate PCA to be an effective tool for detecting changes in the dynamic characteristics of masonry constructions.

The influence of environmental parameters on the dynamic behaviour of the San Frediano bell tower in Lucca

Girardi M;Padovani C;Pellegrini D;
2018

Abstract

This paper aims at assessing the influence of environmental parameters on the modal characteristics of age-old masonry constructions. The results of a long-term ambient vibration monitoring of the San Frediano bell tower in Lucca (Italy) are reported. The tower, dating back to the 11th century, has been fitted along its height with four triaxial seismometric stations, which were left active for about one year. Data from the monitoring system have been processed via the Stochastic Subspace Identification Method in order to identify the tower's modal characteristics and their variations over the year. The dependence of the tower's frequencies on the ambient temperature was first studied and simulated via simple auto-regressive models. Then, some output-only models based on the principal component analysis (PCA) were applied, under the hypotheses of both linear and nonlinear (Kernel PCA) dependence of the natural frequencies on the unknown environmental parameters. The results indicate PCA to be an effective tool for detecting changes in the dynamic characteristics of masonry constructions.
2018
Istituto di Scienza e Tecnologie dell'Informazione "Alessandro Faedo" - ISTI
Environmental variability
Experimental models
Masonry towers
Principal component analysis
Stochastic subspace identification method
Structural health monitoring
File in questo prodotto:
File Dimensione Formato  
prod_380305-doc_128914.pdf

non disponibili

Descrizione: The influence of environmental parameters on the dynamic behaviour of the San Frediano bell tower in Lucca
Tipologia: Versione Editoriale (PDF)
Licenza: Nessuna licenza dichiarata (non attribuibile a prodotti successivi al 2023)
Dimensione 7.04 MB
Formato Adobe PDF
7.04 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
prod_380305-doc_135847.pdf

accesso aperto

Descrizione: Postprint - The influence of environmental parameters on the dynamic behaviour of the San Frediano bell tower in Lucca
Tipologia: Documento in Post-print
Licenza: Nessuna licenza dichiarata (non attribuibile a prodotti successivi al 2023)
Dimensione 17.79 MB
Formato Adobe PDF
17.79 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/339029
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 110
  • ???jsp.display-item.citation.isi??? 89
social impact