We report the development of a dual-gas Quartz-Enhanced Photoacoustic Spectroscopy (QEPAS) sensor operating in the mid-infrared range for the simultaneous detection of 12CH4 and 13CH4. The sensor employs a frequency-modulated multiplexing scheme using two distributed-feedback quantum cascade lasers to independently excite the fundamental (fo) and overtone (f1) vibrational modes of a quartz tuning fork coupled with resonator tubes. The f0-demodulated signal is dedicated to monitoring 12CH4, while the f1-demodulated signal selectively quantifies 13CH4, enabling the analysis of the isotopic composition of methane samples. Calibration measurements demonstrated a linear response of the QEPAS signal to varying 13CH4 concentrations in CH4-based samples diluted in N2, with a precision of 1‰ in detecting isotopic delta ratio variations for 1% CH4 mixtures at 0.8 s integration time. The proposed system is suitable for real-time, high-precision isotopic methane sensing aimed at applications such as environmental monitoring, geochemical tracing, and industrial process control.

Simultaneous Detection of 12CH4, 13CH4, and Related Isotope Ratio Exploiting a Frequency-Multiplexed Mid-Infrared Quartz-Enhanced Photoacoustic Sensor

Arianna Elefante;Pietro Patimisco;Vincenzo Spagnolo;Angelo Sampaolo
2026

Abstract

We report the development of a dual-gas Quartz-Enhanced Photoacoustic Spectroscopy (QEPAS) sensor operating in the mid-infrared range for the simultaneous detection of 12CH4 and 13CH4. The sensor employs a frequency-modulated multiplexing scheme using two distributed-feedback quantum cascade lasers to independently excite the fundamental (fo) and overtone (f1) vibrational modes of a quartz tuning fork coupled with resonator tubes. The f0-demodulated signal is dedicated to monitoring 12CH4, while the f1-demodulated signal selectively quantifies 13CH4, enabling the analysis of the isotopic composition of methane samples. Calibration measurements demonstrated a linear response of the QEPAS signal to varying 13CH4 concentrations in CH4-based samples diluted in N2, with a precision of 1‰ in detecting isotopic delta ratio variations for 1% CH4 mixtures at 0.8 s integration time. The proposed system is suitable for real-time, high-precision isotopic methane sensing aimed at applications such as environmental monitoring, geochemical tracing, and industrial process control.
2026
Istituto di fotonica e nanotecnologie - IFN - Sede Secondaria Bari
frequency multiplexing
isotopic composition analysis
methane isotopologues
quartz-enhanced photoacoustic spectroscopy
simultaneous detection
File in questo prodotto:
File Dimensione Formato  
simultaneous-detection-of-12ch4-13ch4-and-related-isotope-ratio-exploiting-a-frequency-multiplexed-mid-infrared-quartz.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 3.54 MB
Formato Adobe PDF
3.54 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/583141
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact