The structural characterisation of adducts formed by the in vitro reaction of haemoglobin (Hb) with styrene oxide (SO), the most reactive metabolite of the industrial reagent styrene, was obtained by liquid chromatography/electrospray ionisation mass spectrometry (LC/ES-MS) analysis of modified tryptic peptides of human Hb chains. The reactive sites of human Hb towards SO were identified through characterisation of alkylated tryptic peptides by matrix-assisted laser desorption/ionisation with tandem mass spectrometry (MALDI-MS/MS). A procedure was set up based on this characterisation, allowing Hb modification to be assessed by monitoring SO/Hb adducts using HPLC with selected ion recording (SIR) mass spectrometry. By this methodology it was also possible to compare advantages and disadvantages of presently available strategies for the measurement of Hb adducts with SO. The results obtained could most plausibly lead to the optimisation of molecular dosimetry of SO adducts, and the analytical procedure described herein could be applied to the biological monitoring of styrene exposure in the workplace.

Structural analysis of styrene oxide/haemoglobin adducts by mass spectrometry: identification of suitable biomarkers for human exposure evaluation

Mamone G;Pocsfalvi G;Malorni A;
2002

Abstract

The structural characterisation of adducts formed by the in vitro reaction of haemoglobin (Hb) with styrene oxide (SO), the most reactive metabolite of the industrial reagent styrene, was obtained by liquid chromatography/electrospray ionisation mass spectrometry (LC/ES-MS) analysis of modified tryptic peptides of human Hb chains. The reactive sites of human Hb towards SO were identified through characterisation of alkylated tryptic peptides by matrix-assisted laser desorption/ionisation with tandem mass spectrometry (MALDI-MS/MS). A procedure was set up based on this characterisation, allowing Hb modification to be assessed by monitoring SO/Hb adducts using HPLC with selected ion recording (SIR) mass spectrometry. By this methodology it was also possible to compare advantages and disadvantages of presently available strategies for the measurement of Hb adducts with SO. The results obtained could most plausibly lead to the optimisation of molecular dosimetry of SO adducts, and the analytical procedure described herein could be applied to the biological monitoring of styrene exposure in the workplace.
2002
Istituto di Scienze dell'Alimentazione - ISA
LC/ES-MS
MALDI-MS/MS
haemoglobin adducts
styrene oxide
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/69413
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact