The biomechanical behavior of the upper limb can be clinically assessed through the analysis of the kinematics, the dynamics, and measures of motor control. Such measures are usually obtained in a clinical environment with commercial stereoscopic passive-marker devices that allow high sampling frequency, accuracy and precision, but that are, on the other hand, expensive, require a significant amount of time, and are not portable. Consequently, such assessments are available only in clinics. With the aim of developing applications for neurological patients movement analysis in home environment, an experimental study has been conducted to compare the performances of the motion capture system with the Kinect. The comparison was run during anti-gravitary reaching movements. Results show that the Kinect system can be a low-cost alternative to be used as a measuring system to access patients' performances while executing reaching tasks.

Using Kinect for upper-limb functional evaluation in home rehabilitation: A comparison with a 3D stereoscopic passive marker system

Scano;Alessandro;Caimmi;Marco;Malosio;Matteo;Tosatti;Lorenzo Molinari
2014

Abstract

The biomechanical behavior of the upper limb can be clinically assessed through the analysis of the kinematics, the dynamics, and measures of motor control. Such measures are usually obtained in a clinical environment with commercial stereoscopic passive-marker devices that allow high sampling frequency, accuracy and precision, but that are, on the other hand, expensive, require a significant amount of time, and are not portable. Consequently, such assessments are available only in clinics. With the aim of developing applications for neurological patients movement analysis in home environment, an experimental study has been conducted to compare the performances of the motion capture system with the Kinect. The comparison was run during anti-gravitary reaching movements. Results show that the Kinect system can be a low-cost alternative to be used as a measuring system to access patients' performances while executing reaching tasks.
2014
Istituto di Sistemi e Tecnologie Industriali Intelligenti per il Manifatturiero Avanzato - STIIMA (ex ITIA)
Inglese
Biomedical Robotics and Biomechatronics (2014), 5th IEEE RAS & EMBS International Conference on
Biomedical Robotics and Biomechatronics (2014), 5th IEEE RAS & EMBS International Conference on
561
566
978-1-4799-3126-2
Sì, ma tipo non specificato
12-15 Aug. 2014
Sao Paulo, Brazil
Elbow
Indexes
Joints
Kinematics
Motor drives
Robot sensing systems
Shoulder
8
none
Scano, Alessandro; Scano, Alessandro; Caimmi, Marco; Caimmi, Marco; Malosio, Matteo; Malosio, Matteo; MOLINARI TOSATTI, Lorenzo; Molinari, Lorenzo...espandi
273
info:eu-repo/semantics/conferenceObject
04 Contributo in convegno::04.01 Contributo in Atti di convegno
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/260888
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 17
social impact