Scanning capacitance microscopy (SCM) was carried out in the angle beveling configuration on B doped, very narrow quantum wells (QWs) of Si0.75Ge0.25 layers strained between Si films. The majority carrier concentration profiles were calculated from the SCM raw data measured on QWs with a minimum width of 5 nm, doped with different B concentrations ranging from 2x10(16) to 6x10(18) cm(-3). The equilibrium carrier distribution in the heterostructures has been calculated by different simulation approaches, which will be discussed. Moreover, the effect of the biased tip-sample interaction was studied by accurate simulations of the dC/dV vs V characteristics for different positions of the tip moving on the beveled sample surface. The agreement between the experimental and simulated SCM profiles is very good. Thus, a spatial SCM resolution of at least 5 nm was demonstrated on angle beveled samples, not only in terms of signal sensitivity, but also in terms of quantitative majority carrier profiling.

Carrier distribution in quantum nanostructures by scanning capacitance microscopy

Giannazzo F;Raineri V;La Magna A;Mirabella S;Impellizzeri G;Priolo F;Napolitani E;
2005

Abstract

Scanning capacitance microscopy (SCM) was carried out in the angle beveling configuration on B doped, very narrow quantum wells (QWs) of Si0.75Ge0.25 layers strained between Si films. The majority carrier concentration profiles were calculated from the SCM raw data measured on QWs with a minimum width of 5 nm, doped with different B concentrations ranging from 2x10(16) to 6x10(18) cm(-3). The equilibrium carrier distribution in the heterostructures has been calculated by different simulation approaches, which will be discussed. Moreover, the effect of the biased tip-sample interaction was studied by accurate simulations of the dC/dV vs V characteristics for different positions of the tip moving on the beveled sample surface. The agreement between the experimental and simulated SCM profiles is very good. Thus, a spatial SCM resolution of at least 5 nm was demonstrated on angle beveled samples, not only in terms of signal sensitivity, but also in terms of quantitative majority carrier profiling.
2005
Istituto per la Microelettronica e Microsistemi - IMM
Quantum wells
Scanning Capacitance Microscopy
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/40842
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact