The progressive increase in nitrate’s (NO3−) presence in surface and groundwater enhances environmental and human health risks. The aim of this work is the fabrication and characterization of sensitive, real-time, low-cost, and portable amperometric sensors for low NO3− concentration detection in water. Copper (Cu) micro-flowers were electrodeposited on top of carbon screen-printed electrodes (SPCEs) via cyclic voltammetry (with voltage ranging from −1.0 V to 0.0 V at a scan rate of 0.1 V s−1). The obtained sensors exhibited a high catalytic activity toward the electro-reduction in NO3−, with a sensitivity of 44.71 μA/mM. They had a limit of detection of 0.87 µM and a good dynamic linear concentration range from 0.05 to 3 mM. The results were compared to spectrophotometric analysis. In addition, the devices exhibited good stability and a maximum standard deviation (RSD) of 5% after ten measurements; reproducibility, with a maximum RSD of 4%; and repeatability after 10 measurements with the RSD at only 5.63%.

Copper Micro-Flowers for Electrocatalytic Sensing of Nitrate Ions in Water

Farina, Roberta
Writing – Original Draft Preparation
;
D'Arrigo, Giuseppe;Alberti, Alessandra;Scalese, Silvia;Capuano, Giuseppe E.;Corso, Domenico;Libertino, Sebania
Conceptualization
2024

Abstract

The progressive increase in nitrate’s (NO3−) presence in surface and groundwater enhances environmental and human health risks. The aim of this work is the fabrication and characterization of sensitive, real-time, low-cost, and portable amperometric sensors for low NO3− concentration detection in water. Copper (Cu) micro-flowers were electrodeposited on top of carbon screen-printed electrodes (SPCEs) via cyclic voltammetry (with voltage ranging from −1.0 V to 0.0 V at a scan rate of 0.1 V s−1). The obtained sensors exhibited a high catalytic activity toward the electro-reduction in NO3−, with a sensitivity of 44.71 μA/mM. They had a limit of detection of 0.87 µM and a good dynamic linear concentration range from 0.05 to 3 mM. The results were compared to spectrophotometric analysis. In addition, the devices exhibited good stability and a maximum standard deviation (RSD) of 5% after ten measurements; reproducibility, with a maximum RSD of 4%; and repeatability after 10 measurements with the RSD at only 5.63%.
2024
Istituto per la Microelettronica e Microsistemi - IMM
electrocatalytic reaction
electrochemical sensor
electrodeposition
nitrate detection
screen-printed electrodes
File in questo prodotto:
File Dimensione Formato  
171 Farina sensors 2024.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 9.35 MB
Formato Adobe PDF
9.35 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/514870
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? ND
social impact